TJ-II:Ports: Difference between revisions
Jump to navigation
Jump to search
Line 5: | Line 5: | ||
90 ≤ φ ≤ 180 ° | 90 ≤ φ ≤ 180 ° | ||
=== Segment A1 === | |||
{| class="wikitable" align="center" border="1" | {| class="wikitable" align="center" border="1" | ||
!''Port'' !!''Diagnostic or device''!!''Comment'' | !''Port'' !!''Diagnostic or device''!!''Comment'' | ||
Line 15: | Line 16: | ||
|- | |- | ||
|A1TANG|| || | |A1TANG|| || | ||
|} | |||
=== Segment A2 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|A2TOP|| [[TJ-II:Soft_X-rays| Soft X-ray tomography]] || | |A2TOP|| [[TJ-II:Soft_X-rays| Soft X-ray tomography]] || | ||
Line 21: | Line 27: | ||
|- | |- | ||
|A2BOT|| [[TJ-II:Soft_X-rays| Soft X-ray tomography]] || | |A2BOT|| [[TJ-II:Soft_X-rays| Soft X-ray tomography]] || | ||
|} | |||
=== Segment A3 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|A3SIDE|| || | |A3SIDE|| || | ||
|- | |- | ||
|A3BOT|| [[TJ-II:Limiter|Limiter]] || | |A3BOT|| [[TJ-II:Limiter|Limiter]] || | ||
|} | |||
=== Segment A4 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|A4TOP|| [[TJ-II:Reflectometry|AM reflectometer]] (profiles)<br>[[TJ-II:Biasing probe|Biasing probe]] || | |A4TOP|| [[TJ-II:Reflectometry|AM reflectometer]] (profiles)<br>[[TJ-II:Biasing probe|Biasing probe]] || | ||
Line 31: | Line 47: | ||
|- | |- | ||
|A4BOT|| || | |A4BOT|| || | ||
|} | |||
=== Segment A5 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|A5TOP|| Vacuum feedthrough connector for the A5 [[TJ-II:Magnetics|Rogowski coil and diamagnetic loop ]]|| | |A5TOP|| Vacuum feedthrough connector for the A5 [[TJ-II:Magnetics|Rogowski coil and diamagnetic loop ]]|| | ||
Line 37: | Line 58: | ||
|- | |- | ||
|A5BOT|| || | |A5BOT|| || | ||
|} | |||
=== Segment A6 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|A6TOP|| || | |A6TOP|| || | ||
|- | |- | ||
|A6SIDE|| [[TJ-II:Electron Cyclotron Resonant Heating|ECRH]] (QTL2) || | |A6SIDE|| [[TJ-II:Electron Cyclotron Resonant Heating|ECRH]] (QTL2) || | ||
|} | |||
=== Segment A7 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|A7TOP|| || | |A7TOP|| || | ||
Line 47: | Line 78: | ||
|- | |- | ||
|A7BOT|| || | |A7BOT|| || | ||
|} | |||
=== Segment A8 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|A8TOP|| || | |A8TOP|| || |
Revision as of 20:37, 26 November 2010
The table below specifies which diagnostics and devices are connected to each port of TJ-II.
Sector A
90 ≤ φ ≤ 180 °
Segment A1
Port | Diagnostic or device | Comment |
---|---|---|
A1TOP | ||
A1SIDE | ||
A1BOT | ||
A1TANG |
Segment A2
Port | Diagnostic or device | Comment |
---|---|---|
A2TOP | Soft X-ray tomography | |
A2SIDE | Soft X-ray tomography | |
A2BOT | Soft X-ray tomography |
Segment A3
Port | Diagnostic or device | Comment |
---|---|---|
A3SIDE | ||
A3BOT | Limiter |
Segment A4
Port | Diagnostic or device | Comment |
---|---|---|
A4TOP | AM reflectometer (profiles) Biasing probe |
|
A4SIDE | ||
A4BOT |
Segment A5
Port | Diagnostic or device | Comment |
---|---|---|
A5TOP | Vacuum feedthrough connector for the A5 Rogowski coil and diamagnetic loop | |
A5SIDE | ||
A5BOT |
Segment A6
Port | Diagnostic or device | Comment |
---|---|---|
A6TOP | ||
A6SIDE | ECRH (QTL2) |
Segment A7
Port | Diagnostic or device | Comment |
---|---|---|
A7TOP | ||
A7SIDE | Charge exchange spectroscopy Diagnostic neutral beam |
|
A7BOT |
Segment A8
Port | Diagnostic or device | Comment |
---|---|---|
A8TOP | ||
A8SIDE | ||
A8BOT | ||
A8TANG |
Sector B
180 ≤ φ ≤ 270 °
Port | Diagnostic or device | Comment |
---|---|---|
B1TOP | ||
B1SIDE | ||
B1BOT | ||
B1TANG | Compact Neutral Particle Analyzer | |
B2TOP | ||
B2SIDE | Pellet injector | |
B2BOT | Langmuir Probes | |
B3SIDE | ECRH (QTL1) | |
B3BOT | ||
B4TOP | Heavy Ion Beam Probe (injection) | |
B4SIDE | Heavy Ion Beam Probe (spectrometer) Vacuum feedthrough connector for the B4 Rogowski coil and diamagnetic loop |
|
B4BOT | ||
B5TOP | Vacuum feedthrough connector for the second Mirnov coil straight vertical array | |
B5SIDE | ||
B5BOT | ||
B6TOP | ||
B6SIDE | ||
B7TOP | Multichannel Bolometry | |
B7SIDE | Multichannel Bolometry | |
B7BOT | ||
B8TOP | Microwave interferometer | |
B8SIDE | Spectroscopy (toroidal rotation) | |
B8BOT | Microwave interferometer | |
B8TANG | Fast camera |
Sector C
270 ≤ φ ≤ 360 °
Port | Diagnostic or device | Comment |
---|---|---|
C1TOP | ||
C1SIDE | ||
C1BOT | ||
C1TANG | NBI 1 | |
C2TOP | ||
C2SIDE | ||
C2BOT | ||
C3SIDE | ||
C3BOT | Limiter | |
C4TOP | Vacuum feedthrough connector for the first Mirnov coil straight vertical array | |
C4SIDE | ||
C4BOT | ||
C5TOP | ||
C5SIDE | ||
C5BOT | ||
C6TOP | Doppler Reflectometer (Mirror) | |
C6SIDE | Doppler Reflectometer (Antenna) | |
C7TOP | Lithium Beam | |
C7SIDE | ||
C7BOT | ||
C8TOP | Helium Beam | |
C8SIDE | Helium Beam | |
C8BOT | Helium Beam | |
C8TANG |
Sector D
0 ≤ φ ≤ 90 °
Port | Diagnostic or device | Comment |
---|---|---|
D1TOP | ||
D1SIDE | ||
D1BOT | ||
D1TANG | ||
D2TOP | Thomson Scattering (laser view dump) | |
D2SIDE | Thomson Scattering (polychromator) | |
D2BOT | Thomson Scattering (laser entry) | |
D3SIDE | ||
D3BOT | ||
D4TOP | Langmuir probe | |
D4SIDE | ||
D4BOT | ||
D5TOP | ||
D5SIDE | ||
D5BOT | ||
D6TOP | Bernstein Wave Heating (mirror) | |
D6SIDE | Bernstein Wave Heating | |
D7TOP | ||
D7SIDE | ||
D7BOT | ||
D8TOP | ||
D8SIDE | Spectroscopy (toroidal rotation) | |
D8BOT | ||
D8TANG | NBI 2 |