TJ-II:Ports: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
| Line 1: | Line 1: | ||
The | The listing below specifies which diagnostics and devices are connected to each port of [[TJ-II]]. | ||
__NOTOC__ | |||
== [[TJ-II:Sectors|Sector A]] == | == [[TJ-II:Sectors|Sector A]] == | ||
Revision as of 20:52, 26 November 2010
The listing below specifies which diagnostics and devices are connected to each port of TJ-II.
Sector A
90 ≤ φ ≤ 180 °
Segment A1
| Port | Diagnostic or device | Comment |
|---|---|---|
| A1TOP | ||
| A1SIDE | ||
| A1BOT | ||
| A1TANG |
Segment A2
| Port | Diagnostic or device | Comment |
|---|---|---|
| A2TOP | Soft X-ray tomography | |
| A2SIDE | Soft X-ray tomography | |
| A2BOT | Soft X-ray tomography |
Segment A3
| Port | Diagnostic or device | Comment |
|---|---|---|
| A3SIDE | ||
| A3BOT | Limiter |
Segment A4
| Port | Diagnostic or device | Comment |
|---|---|---|
| A4TOP | AM reflectometer (profiles) Biasing probe |
|
| A4SIDE | ||
| A4BOT |
Segment A5
| Port | Diagnostic or device | Comment |
|---|---|---|
| A5TOP | Vacuum feedthrough connector for the A5 Rogowski coil and diamagnetic loop | |
| A5SIDE | ||
| A5BOT |
Segment A6
| Port | Diagnostic or device | Comment |
|---|---|---|
| A6TOP | ||
| A6SIDE | ECRH (QTL2) |
Segment A7
| Port | Diagnostic or device | Comment |
|---|---|---|
| A7TOP | ||
| A7SIDE | Charge exchange spectroscopy Diagnostic neutral beam |
|
| A7BOT |
Segment A8
| Port | Diagnostic or device | Comment |
|---|---|---|
| A8TOP | ||
| A8SIDE | ||
| A8BOT | ||
| A8TANG |
Sector B
180 ≤ φ ≤ 270 °
Segment B1
| Port | Diagnostic or device | Comment |
|---|---|---|
| B1TOP | ||
| B1SIDE | ||
| B1BOT | ||
| B1TANG | Compact Neutral Particle Analyzer |
Segment B2
| Port | Diagnostic or device | Comment |
|---|---|---|
| B2TOP | ||
| B2SIDE | Pellet injector | |
| B2BOT | Langmuir Probes |
Segment B3
| Port | Diagnostic or device | Comment |
|---|---|---|
| B3SIDE | ECRH (QTL1) | |
| B3BOT |
Segment B4
| Port | Diagnostic or device | Comment |
|---|---|---|
| B4TOP | Heavy Ion Beam Probe (injection) | |
| B4SIDE | Heavy Ion Beam Probe (spectrometer) Vacuum feedthrough connector for the B4 Rogowski coil and diamagnetic loop |
|
| B4BOT |
Segment B5
| Port | Diagnostic or device | Comment |
|---|---|---|
| B5TOP | Vacuum feedthrough connector for the second Mirnov coil straight vertical array | |
| B5SIDE | ||
| B5BOT |
Segment B6
| Port | Diagnostic or device | Comment |
|---|---|---|
| B6TOP | ||
| B6SIDE |
Segment B7
| Port | Diagnostic or device | Comment |
|---|---|---|
| B7TOP | Multichannel Bolometry | |
| B7SIDE | Multichannel Bolometry | |
| B7BOT |
Segment B8
| Port | Diagnostic or device | Comment |
|---|---|---|
| B8TOP | Microwave interferometer | |
| B8SIDE | Spectroscopy (toroidal rotation) | |
| B8BOT | Microwave interferometer | |
| B8TANG | Fast camera |
Sector C
270 ≤ φ ≤ 360 °
Segment C1
| Port | Diagnostic or device | Comment |
|---|---|---|
| C1TOP | ||
| C1SIDE | ||
| C1BOT | ||
| C1TANG | NBI 1 |
Segment C2
| Port | Diagnostic or device | Comment |
|---|---|---|
| C2TOP | ||
| C2SIDE | ||
| C2BOT |
Segment C3
| Port | Diagnostic or device | Comment |
|---|---|---|
| C3SIDE | ||
| C3BOT | Limiter |
Segment C4
| Port | Diagnostic or device | Comment |
|---|---|---|
| C4TOP | Vacuum feedthrough connector for the first Mirnov coil straight vertical array | |
| C4SIDE | ||
| C4BOT |
Segment C5
| Port | Diagnostic or device | Comment |
|---|---|---|
| C5TOP | ||
| C5SIDE | ||
| C5BOT |
Segment C6
| Port | Diagnostic or device | Comment |
|---|---|---|
| C6TOP | Doppler Reflectometer (Mirror) | |
| C6SIDE | Doppler Reflectometer (Antenna) |
Segment C7
| Port | Diagnostic or device | Comment |
|---|---|---|
| C7TOP | Lithium Beam | |
| C7SIDE | ||
| C7BOT |
Segment C8
| Port | Diagnostic or device | Comment |
|---|---|---|
| C8TOP | Helium Beam | |
| C8SIDE | Helium Beam | |
| C8BOT | Helium Beam | |
| C8TANG |
Sector D
0 ≤ φ ≤ 90 °
Segment D1
| Port | Diagnostic or device | Comment |
|---|---|---|
| D1TOP | ||
| D1SIDE | ||
| D1BOT | ||
| D1TANG |
Segment D2
| Port | Diagnostic or device | Comment |
|---|---|---|
| D2TOP | Thomson Scattering (laser view dump) | |
| D2SIDE | Thomson Scattering (polychromator) | |
| D2BOT | Thomson Scattering (laser entry) |
Segment D3
| Port | Diagnostic or device | Comment |
|---|---|---|
| D3SIDE | ||
| D3BOT |
Segment D4
| Port | Diagnostic or device | Comment |
|---|---|---|
| D4TOP | Langmuir probe | |
| D4SIDE | ||
| D4BOT |
Segment D5
| Port | Diagnostic or device | Comment |
|---|---|---|
| D5TOP | ||
| D5SIDE | ||
| D5BOT |
Segment D6
| Port | Diagnostic or device | Comment |
|---|---|---|
| D6TOP | Bernstein Wave Heating (mirror) | |
| D6SIDE | Bernstein Wave Heating |
Segment D7
| Port | Diagnostic or device | Comment |
|---|---|---|
| D7TOP | ||
| D7SIDE | ||
| D7BOT |
Segment D8
| Port | Diagnostic or device | Comment |
|---|---|---|
| D8TOP | ||
| D8SIDE | Spectroscopy (toroidal rotation) | |
| D8BOT | ||
| D8TANG | NBI 2 |