TJ-II:Ports: Difference between revisions
Jump to navigation
Jump to search
Line 281: | Line 281: | ||
0 ≤ φ ≤ 90 ° | 0 ≤ φ ≤ 90 ° | ||
=== Segment D1 === | |||
{| class="wikitable" align="center" border="1" | {| class="wikitable" align="center" border="1" | ||
!''Port'' !!''Diagnostic or device''!!''Comment'' | !''Port'' !!''Diagnostic or device''!!''Comment'' | ||
Line 291: | Line 292: | ||
|- | |- | ||
|D1TANG|| || | |D1TANG|| || | ||
|} | |||
=== Segment D2 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|D2TOP|| [[TJ-II:Thomson Scattering|Thomson Scattering]] (laser view dump) || | |D2TOP|| [[TJ-II:Thomson Scattering|Thomson Scattering]] (laser view dump) || | ||
Line 297: | Line 303: | ||
|- | |- | ||
|D2BOT|| [[TJ-II:Thomson Scattering|Thomson Scattering]] (laser entry)|| | |D2BOT|| [[TJ-II:Thomson Scattering|Thomson Scattering]] (laser entry)|| | ||
|} | |||
=== Segment D3 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|D3SIDE|| || | |D3SIDE|| || | ||
|- | |- | ||
|D3BOT|| || | |D3BOT|| || | ||
|} | |||
=== Segment D4 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|D4TOP|| [[TJ-II:Langmuir Probes|Langmuir probe]] || | |D4TOP|| [[TJ-II:Langmuir Probes|Langmuir probe]] || | ||
Line 307: | Line 323: | ||
|- | |- | ||
|D4BOT|| || | |D4BOT|| || | ||
|} | |||
=== Segment D5 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|D5TOP|| || | |D5TOP|| || | ||
Line 313: | Line 334: | ||
|- | |- | ||
|D5BOT|| || | |D5BOT|| || | ||
|} | |||
=== Segment D6 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|D6TOP|| [[TJ-II:Electron_Bernstein_Wave_Heating|Bernstein Wave Heating]] (mirror) || | |D6TOP|| [[TJ-II:Electron_Bernstein_Wave_Heating|Bernstein Wave Heating]] (mirror) || | ||
|- | |- | ||
|D6SIDE|| [[TJ-II:Electron_Bernstein_Wave_Heating|Bernstein Wave Heating]] || | |D6SIDE|| [[TJ-II:Electron_Bernstein_Wave_Heating|Bernstein Wave Heating]] || | ||
|} | |||
=== Segment D7 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|D7TOP|| || | |D7TOP|| || | ||
Line 323: | Line 354: | ||
|- | |- | ||
|D7BOT|| || | |D7BOT|| || | ||
|} | |||
=== Segment D8 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|D8TOP|| || | |D8TOP|| || |
Revision as of 20:44, 26 November 2010
The table below specifies which diagnostics and devices are connected to each port of TJ-II.
Sector A
90 ≤ φ ≤ 180 °
Segment A1
Port | Diagnostic or device | Comment |
---|---|---|
A1TOP | ||
A1SIDE | ||
A1BOT | ||
A1TANG |
Segment A2
Port | Diagnostic or device | Comment |
---|---|---|
A2TOP | Soft X-ray tomography | |
A2SIDE | Soft X-ray tomography | |
A2BOT | Soft X-ray tomography |
Segment A3
Port | Diagnostic or device | Comment |
---|---|---|
A3SIDE | ||
A3BOT | Limiter |
Segment A4
Port | Diagnostic or device | Comment |
---|---|---|
A4TOP | AM reflectometer (profiles) Biasing probe |
|
A4SIDE | ||
A4BOT |
Segment A5
Port | Diagnostic or device | Comment |
---|---|---|
A5TOP | Vacuum feedthrough connector for the A5 Rogowski coil and diamagnetic loop | |
A5SIDE | ||
A5BOT |
Segment A6
Port | Diagnostic or device | Comment |
---|---|---|
A6TOP | ||
A6SIDE | ECRH (QTL2) |
Segment A7
Port | Diagnostic or device | Comment |
---|---|---|
A7TOP | ||
A7SIDE | Charge exchange spectroscopy Diagnostic neutral beam |
|
A7BOT |
Segment A8
Port | Diagnostic or device | Comment |
---|---|---|
A8TOP | ||
A8SIDE | ||
A8BOT | ||
A8TANG |
Sector B
180 ≤ φ ≤ 270 °
Segment B1
Port | Diagnostic or device | Comment |
---|---|---|
B1TOP | ||
B1SIDE | ||
B1BOT | ||
B1TANG | Compact Neutral Particle Analyzer |
Segment B2
Port | Diagnostic or device | Comment |
---|---|---|
B2TOP | ||
B2SIDE | Pellet injector | |
B2BOT | Langmuir Probes |
Segment B3
Port | Diagnostic or device | Comment |
---|---|---|
B3SIDE | ECRH (QTL1) | |
B3BOT |
Segment B4
Port | Diagnostic or device | Comment |
---|---|---|
B4TOP | Heavy Ion Beam Probe (injection) | |
B4SIDE | Heavy Ion Beam Probe (spectrometer) Vacuum feedthrough connector for the B4 Rogowski coil and diamagnetic loop |
|
B4BOT |
Segment B5
Port | Diagnostic or device | Comment |
---|---|---|
B5TOP | Vacuum feedthrough connector for the second Mirnov coil straight vertical array | |
B5SIDE | ||
B5BOT |
Segment B6
Port | Diagnostic or device | Comment |
---|---|---|
B6TOP | ||
B6SIDE |
Segment B7
Port | Diagnostic or device | Comment |
---|---|---|
B7TOP | Multichannel Bolometry | |
B7SIDE | Multichannel Bolometry | |
B7BOT |
Segment B8
Port | Diagnostic or device | Comment |
---|---|---|
B8TOP | Microwave interferometer | |
B8SIDE | Spectroscopy (toroidal rotation) | |
B8BOT | Microwave interferometer | |
B8TANG | Fast camera |
Sector C
270 ≤ φ ≤ 360 °
Segment C1
Port | Diagnostic or device | Comment |
---|---|---|
C1TOP | ||
C1SIDE | ||
C1BOT | ||
C1TANG | NBI 1 |
Segment C2
Port | Diagnostic or device | Comment |
---|---|---|
C2TOP | ||
C2SIDE | ||
C2BOT |
Segment C3
Port | Diagnostic or device | Comment |
---|---|---|
C3SIDE | ||
C3BOT | Limiter |
Segment C4
Port | Diagnostic or device | Comment |
---|---|---|
C4TOP | Vacuum feedthrough connector for the first Mirnov coil straight vertical array | |
C4SIDE | ||
C4BOT |
Segment C5
Port | Diagnostic or device | Comment |
---|---|---|
C5TOP | ||
C5SIDE | ||
C5BOT |
Segment C6
Port | Diagnostic or device | Comment |
---|---|---|
C6TOP | Doppler Reflectometer (Mirror) | |
C6SIDE | Doppler Reflectometer (Antenna) |
Segment C7
Port | Diagnostic or device | Comment |
---|---|---|
C7TOP | Lithium Beam | |
C7SIDE | ||
C7BOT |
Segment C8
Port | Diagnostic or device | Comment |
---|---|---|
C8TOP | Helium Beam | |
C8SIDE | Helium Beam | |
C8BOT | Helium Beam | |
C8TANG |
Sector D
0 ≤ φ ≤ 90 °
Segment D1
Port | Diagnostic or device | Comment |
---|---|---|
D1TOP | ||
D1SIDE | ||
D1BOT | ||
D1TANG |
Segment D2
Port | Diagnostic or device | Comment |
---|---|---|
D2TOP | Thomson Scattering (laser view dump) | |
D2SIDE | Thomson Scattering (polychromator) | |
D2BOT | Thomson Scattering (laser entry) |
Segment D3
Port | Diagnostic or device | Comment |
---|---|---|
D3SIDE | ||
D3BOT |
Segment D4
Port | Diagnostic or device | Comment |
---|---|---|
D4TOP | Langmuir probe | |
D4SIDE | ||
D4BOT |
Segment D5
Port | Diagnostic or device | Comment |
---|---|---|
D5TOP | ||
D5SIDE | ||
D5BOT |
Segment D6
Port | Diagnostic or device | Comment |
---|---|---|
D6TOP | Bernstein Wave Heating (mirror) | |
D6SIDE | Bernstein Wave Heating |
Segment D7
Port | Diagnostic or device | Comment |
---|---|---|
D7TOP | ||
D7SIDE | ||
D7BOT |
Segment D8
Port | Diagnostic or device | Comment |
---|---|---|
D8TOP | ||
D8SIDE | Spectroscopy (toroidal rotation) | |
D8BOT | ||
D8TANG | NBI 2 |