TJ-II:Ports: Difference between revisions
Jump to navigation
Jump to search
| Line 97: | Line 97: | ||
180 ≤ φ ≤ 270 ° | 180 ≤ φ ≤ 270 ° | ||
=== Segment B1 === | |||
{| class="wikitable" align="center" border="1" | {| class="wikitable" align="center" border="1" | ||
!''Port'' !!''Diagnostic or device''!!''Comment'' | !''Port'' !!''Diagnostic or device''!!''Comment'' | ||
| Line 107: | Line 108: | ||
|- | |- | ||
|B1TANG|| [[TJ-II:Compact Neutral Particle Analyzer|Compact Neutral Particle Analyzer]] || | |B1TANG|| [[TJ-II:Compact Neutral Particle Analyzer|Compact Neutral Particle Analyzer]] || | ||
|} | |||
=== Segment B2 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|B2TOP|| || | |B2TOP|| || | ||
| Line 113: | Line 119: | ||
|- | |- | ||
|B2BOT|| [[TJ-II:Langmuir Probes|Langmuir Probes]] || | |B2BOT|| [[TJ-II:Langmuir Probes|Langmuir Probes]] || | ||
|} | |||
=== Segment B3 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|B3SIDE|| [[TJ-II:Electron Cyclotron Resonant Heating|ECRH]] (QTL1) || | |B3SIDE|| [[TJ-II:Electron Cyclotron Resonant Heating|ECRH]] (QTL1) || | ||
|- | |- | ||
|B3BOT|| || | |B3BOT|| || | ||
|} | |||
=== Segment B4 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|B4TOP|| [[TJ-II:Heavy Ion Beam Probe|Heavy Ion Beam Probe]] (injection)|| | |B4TOP|| [[TJ-II:Heavy Ion Beam Probe|Heavy Ion Beam Probe]] (injection)|| | ||
| Line 123: | Line 139: | ||
|- | |- | ||
|B4BOT|| || | |B4BOT|| || | ||
|} | |||
=== Segment B5 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|B5TOP|| Vacuum feedthrough connector for the second [[TJ-II:Magnetics|Mirnov coil straight vertical array]] || | |B5TOP|| Vacuum feedthrough connector for the second [[TJ-II:Magnetics|Mirnov coil straight vertical array]] || | ||
| Line 129: | Line 150: | ||
|- | |- | ||
|B5BOT|| || | |B5BOT|| || | ||
|} | |||
=== Segment B6 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|B6TOP|| || | |B6TOP|| || | ||
|- | |- | ||
|B6SIDE|| || | |B6SIDE|| || | ||
|} | |||
=== Segment B7 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|B7TOP|| [[TJ-II:Bolometry|Multichannel Bolometry]] || | |B7TOP|| [[TJ-II:Bolometry|Multichannel Bolometry]] || | ||
| Line 139: | Line 170: | ||
|- | |- | ||
|B7BOT|| || | |B7BOT|| || | ||
|} | |||
=== Segment B8 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|B8TOP|| [[TJ-II:Interferometry|Microwave interferometer]] || | |B8TOP|| [[TJ-II:Interferometry|Microwave interferometer]] || | ||
Revision as of 20:40, 26 November 2010
The table below specifies which diagnostics and devices are connected to each port of TJ-II.
Sector A
90 ≤ φ ≤ 180 °
Segment A1
| Port | Diagnostic or device | Comment |
|---|---|---|
| A1TOP | ||
| A1SIDE | ||
| A1BOT | ||
| A1TANG |
Segment A2
| Port | Diagnostic or device | Comment |
|---|---|---|
| A2TOP | Soft X-ray tomography | |
| A2SIDE | Soft X-ray tomography | |
| A2BOT | Soft X-ray tomography |
Segment A3
| Port | Diagnostic or device | Comment |
|---|---|---|
| A3SIDE | ||
| A3BOT | Limiter |
Segment A4
| Port | Diagnostic or device | Comment |
|---|---|---|
| A4TOP | AM reflectometer (profiles) Biasing probe |
|
| A4SIDE | ||
| A4BOT |
Segment A5
| Port | Diagnostic or device | Comment |
|---|---|---|
| A5TOP | Vacuum feedthrough connector for the A5 Rogowski coil and diamagnetic loop | |
| A5SIDE | ||
| A5BOT |
Segment A6
| Port | Diagnostic or device | Comment |
|---|---|---|
| A6TOP | ||
| A6SIDE | ECRH (QTL2) |
Segment A7
| Port | Diagnostic or device | Comment |
|---|---|---|
| A7TOP | ||
| A7SIDE | Charge exchange spectroscopy Diagnostic neutral beam |
|
| A7BOT |
Segment A8
| Port | Diagnostic or device | Comment |
|---|---|---|
| A8TOP | ||
| A8SIDE | ||
| A8BOT | ||
| A8TANG |
Sector B
180 ≤ φ ≤ 270 °
Segment B1
| Port | Diagnostic or device | Comment |
|---|---|---|
| B1TOP | ||
| B1SIDE | ||
| B1BOT | ||
| B1TANG | Compact Neutral Particle Analyzer |
Segment B2
| Port | Diagnostic or device | Comment |
|---|---|---|
| B2TOP | ||
| B2SIDE | Pellet injector | |
| B2BOT | Langmuir Probes |
Segment B3
| Port | Diagnostic or device | Comment |
|---|---|---|
| B3SIDE | ECRH (QTL1) | |
| B3BOT |
Segment B4
| Port | Diagnostic or device | Comment |
|---|---|---|
| B4TOP | Heavy Ion Beam Probe (injection) | |
| B4SIDE | Heavy Ion Beam Probe (spectrometer) Vacuum feedthrough connector for the B4 Rogowski coil and diamagnetic loop |
|
| B4BOT |
Segment B5
| Port | Diagnostic or device | Comment |
|---|---|---|
| B5TOP | Vacuum feedthrough connector for the second Mirnov coil straight vertical array | |
| B5SIDE | ||
| B5BOT |
Segment B6
| Port | Diagnostic or device | Comment |
|---|---|---|
| B6TOP | ||
| B6SIDE |
Segment B7
| Port | Diagnostic or device | Comment |
|---|---|---|
| B7TOP | Multichannel Bolometry | |
| B7SIDE | Multichannel Bolometry | |
| B7BOT |
Segment B8
| Port | Diagnostic or device | Comment |
|---|---|---|
| B8TOP | Microwave interferometer | |
| B8SIDE | Spectroscopy (toroidal rotation) | |
| B8BOT | Microwave interferometer | |
| B8TANG | Fast camera |
Sector C
270 ≤ φ ≤ 360 °
| Port | Diagnostic or device | Comment |
|---|---|---|
| C1TOP | ||
| C1SIDE | ||
| C1BOT | ||
| C1TANG | NBI 1 | |
| C2TOP | ||
| C2SIDE | ||
| C2BOT | ||
| C3SIDE | ||
| C3BOT | Limiter | |
| C4TOP | Vacuum feedthrough connector for the first Mirnov coil straight vertical array | |
| C4SIDE | ||
| C4BOT | ||
| C5TOP | ||
| C5SIDE | ||
| C5BOT | ||
| C6TOP | Doppler Reflectometer (Mirror) | |
| C6SIDE | Doppler Reflectometer (Antenna) | |
| C7TOP | Lithium Beam | |
| C7SIDE | ||
| C7BOT | ||
| C8TOP | Helium Beam | |
| C8SIDE | Helium Beam | |
| C8BOT | Helium Beam | |
| C8TANG |
Sector D
0 ≤ φ ≤ 90 °
| Port | Diagnostic or device | Comment |
|---|---|---|
| D1TOP | ||
| D1SIDE | ||
| D1BOT | ||
| D1TANG | ||
| D2TOP | Thomson Scattering (laser view dump) | |
| D2SIDE | Thomson Scattering (polychromator) | |
| D2BOT | Thomson Scattering (laser entry) | |
| D3SIDE | ||
| D3BOT | ||
| D4TOP | Langmuir probe | |
| D4SIDE | ||
| D4BOT | ||
| D5TOP | ||
| D5SIDE | ||
| D5BOT | ||
| D6TOP | Bernstein Wave Heating (mirror) | |
| D6SIDE | Bernstein Wave Heating | |
| D7TOP | ||
| D7SIDE | ||
| D7BOT | ||
| D8TOP | ||
| D8SIDE | Spectroscopy (toroidal rotation) | |
| D8BOT | ||
| D8TANG | NBI 2 |