The | The listing below specifies which diagnostics and devices are connected to each port of [[TJ-II]]. | ||
__NOTOC__ | |||
== [[TJ-II:Sectors|Sector A]] == | |||
90 ≤ φ ≤ 180 ° | |||
=== Segment A1 === | |||
{| class="wikitable" align="center" border="1" | {| class="wikitable" align="center" border="1" | ||
!''Port'' !!''Diagnostic or device''!!''Comment'' | !''Port'' !!''Diagnostic or device''!!''Comment'' | ||
Line 13: | Line 16: | ||
|- | |- | ||
|A1TANG|| || | |A1TANG|| || | ||
|} | |||
=== Segment A2 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|A2TOP|| [[TJ-II:Soft_X-rays| Soft X-ray tomography]] || | |A2TOP|| [[TJ-II:Soft_X-rays| Soft X-ray tomography]] || | ||
Line 19: | Line 27: | ||
|- | |- | ||
|A2BOT|| [[TJ-II:Soft_X-rays| Soft X-ray tomography]] || | |A2BOT|| [[TJ-II:Soft_X-rays| Soft X-ray tomography]] || | ||
|} | |||
=== Segment A3 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|A3SIDE|| || | |A3SIDE|| || | ||
|- | |- | ||
|A3BOT|| [[TJ-II:Limiter|Limiter]] || | |A3BOT|| [[TJ-II:Limiter|Limiter]] || | ||
|} | |||
=== Segment A4 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|A4TOP|| || | |A4TOP|| [[TJ-II:Reflectometry|AM reflectometer]] (profiles)<br>[[TJ-II:Heavy Ion Beam Probe|Heavy Ion Beam Probe 2]] (injection) || | ||
|- | |- | ||
|A4SIDE|| || | |A4SIDE|| [[TJ-II:Heavy Ion Beam Probe|Heavy Ion Beam Probe 2]] (spectrometer) || | ||
|- | |- | ||
|A4BOT|| || | |A4BOT|| || | ||
|} | |||
=== Segment A5 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|A5TOP|| || | |A5TOP|| Vacuum feedthrough connector for the A5 [[TJ-II:Magnetics|Rogowski coil and diamagnetic loop ]]|| | ||
|- | |- | ||
|A5SIDE|| || | |A5SIDE|| || | ||
|- | |- | ||
|A5BOT|| || | |A5BOT|| || | ||
|} | |||
=== Segment A6 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|A6TOP|| || | |A6TOP|| || | ||
|- | |- | ||
|A6SIDE|| [[TJ-II:Electron Cyclotron Resonant Heating|ECRH]] (QTL2) || | |A6SIDE|| [[TJ-II:Electron Cyclotron Resonant Heating|ECRH]] (QTL2) || | ||
|} | |||
=== Segment A7 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|A7TOP|| || | |A7TOP|| [[TJ-II:Biasing probe|Biasing probe]]|| | ||
|- | |- | ||
|A7SIDE|| [[TJ-II:Charge_exchange_spectroscopy|Charge exchange spectroscopy]] || | |A7SIDE|| [[TJ-II:Charge_exchange_spectroscopy|Charge exchange spectroscopy]] <br> [[TJ-II:Diagnostic neutral beam|Diagnostic neutral beam]]|| | ||
|- | |- | ||
|A7BOT|| || | |A7BOT|| || | ||
|} | |||
=== Segment A8 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|A8TOP|| | |A8TOP|| || | ||
|- | |- | ||
|A8SIDE|| | |A8SIDE|| || | ||
|- | |- | ||
|A8BOT|| | |A8BOT|| || | ||
|- | |- | ||
|A8TANG|| || | |A8TANG|| || | ||
Line 57: | Line 95: | ||
== [[TJ-II:Sectors|Sector B]] == | == [[TJ-II:Sectors|Sector B]] == | ||
180 ≤ φ ≤ 270 ° | |||
=== Segment B1 === | |||
{| class="wikitable" align="center" border="1" | {| class="wikitable" align="center" border="1" | ||
!''Port'' !!''Diagnostic or device''!!''Comment'' | !''Port'' !!''Diagnostic or device''!!''Comment'' | ||
Line 66: | Line 107: | ||
|B1BOT|| || | |B1BOT|| || | ||
|- | |- | ||
|B1TANG|| || | |B1TANG|| [[TJ-II:Compact Neutral Particle Analyzer|Compact Neutral Particle Analyzer]] || | ||
|} | |||
=== Segment B2 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|B2TOP|| || | |B2TOP|| || | ||
|- | |- | ||
|B2SIDE|| || | |B2SIDE|| [[TJ-II:Pellet injector|Pellet injector]] || | ||
|- | |- | ||
|B2BOT|| || | |B2BOT|| [[TJ-II:Langmuir Probes|Langmuir Probes]] || | ||
|} | |||
=== Segment B3 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|B3SIDE|| [[TJ-II:Electron Cyclotron Resonant Heating|ECRH]] (QTL1) || | |B3SIDE|| [[TJ-II:Electron Cyclotron Resonant Heating|ECRH]] (QTL1) || | ||
|- | |- | ||
|B3BOT|| || | |B3BOT|| || | ||
|} | |||
=== Segment B4 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|B4TOP|| || | |B4TOP|| [[TJ-II:Heavy Ion Beam Probe|Heavy Ion Beam Probe 1]] (injection)|| | ||
|- | |- | ||
|B4SIDE|| || | |B4SIDE|| [[TJ-II:Heavy Ion Beam Probe|Heavy Ion Beam Probe 1]] (spectrometer) <br>Vacuum feedthrough connector for the B4 [[TJ-II:Magnetics|Rogowski coil and diamagnetic loop]] || | ||
|- | |- | ||
|B4BOT|| || | |B4BOT|| || | ||
|} | |||
=== Segment B5 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|B5TOP|| || | |B5TOP|| Vacuum feedthrough connector for the second [[TJ-II:Magnetics|Mirnov coil straight vertical array]] || | ||
|- | |- | ||
|B5SIDE|| || | |B5SIDE|| || | ||
|- | |- | ||
|B5BOT|| || | |B5BOT|| || | ||
|} | |||
=== Segment B6 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|B6TOP|| || | |B6TOP|| || | ||
|- | |- | ||
|B6SIDE|| || | |B6SIDE|| || | ||
|} | |||
=== Segment B7 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|B7TOP|| [[TJ-II:Bolometry|Multichannel Bolometry]] || | |B7TOP|| [[TJ-II:Bolometry|Multichannel Bolometry]] || | ||
Line 99: | Line 170: | ||
|- | |- | ||
|B7BOT|| || | |B7BOT|| || | ||
|} | |||
=== Segment B8 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|B8TOP|| [[TJ-II:Interferometry|Microwave interferometer]] || | |B8TOP|| [[TJ-II:Interferometry|Microwave interferometer]] || | ||
|- | |- | ||
|B8SIDE|| || | |B8SIDE|| [[TJ-II:Spectroscopy|Spectroscopy]] (toroidal rotation) || | ||
|- | |- | ||
|B8BOT|| [[TJ-II:Interferometry|Microwave interferometer]] || | |B8BOT|| [[TJ-II:Interferometry|Microwave interferometer]] || | ||
|- | |- | ||
|B8TANG|| || | |B8TANG|| [[TJ-II:Fast camera|Fast camera]] || | ||
|} | |} | ||
== [[TJ-II:Sectors|Sector C]] == | == [[TJ-II:Sectors|Sector C]] == | ||
270 ≤ φ ≤ 360 ° | |||
=== Segment C1 === | |||
{| class="wikitable" align="center" border="1" | {| class="wikitable" align="center" border="1" | ||
!''Port'' !!''Diagnostic or device''!!''Comment'' | !''Port'' !!''Diagnostic or device''!!''Comment'' | ||
Line 121: | Line 200: | ||
|- | |- | ||
|C1TANG|| [[TJ-II:Neutral Beam Injection|NBI 1]]|| | |C1TANG|| [[TJ-II:Neutral Beam Injection|NBI 1]]|| | ||
|} | |||
=== Segment C2 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|C2TOP|| || | |C2TOP|| || | ||
Line 127: | Line 211: | ||
|- | |- | ||
|C2BOT|| || | |C2BOT|| || | ||
|} | |||
=== Segment C3 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|C3SIDE|| || | |C3SIDE|| || | ||
|- | |- | ||
|C3BOT|| [[TJ-II:Limiter|Limiter]] || | |C3BOT|| [[TJ-II:Limiter|Limiter]] || | ||
|} | |||
=== Segment C4 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|C4TOP|| || | |C4TOP|| Vacuum feedthrough connector for the first [[TJ-II:Magnetics|Mirnov coil straight vertical array]] || | ||
|- | |- | ||
|C4SIDE|| || | |C4SIDE|| || | ||
|- | |- | ||
|C4BOT|| || | |C4BOT|| || | ||
|} | |||
=== Segment C5 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|C5TOP|| || | |C5TOP|| || | ||
Line 143: | Line 242: | ||
|- | |- | ||
|C5BOT|| || | |C5BOT|| || | ||
|} | |||
=== Segment C6 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|C6TOP|| [[TJ-II:Reflectometry#Doppler_Reflectometer|Doppler Reflectometer]] || | |C6TOP|| [[TJ-II:Reflectometry#Doppler_Reflectometer|Doppler Reflectometer]] (Mirror) || | ||
|- | |- | ||
|C6SIDE|| [[TJ-II:Reflectometry#Doppler_Reflectometer|Doppler Reflectometer]] || | |C6SIDE|| [[TJ-II:Reflectometry#Doppler_Reflectometer|Doppler Reflectometer]] (Antenna) || | ||
|} | |||
=== Segment C7 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|C7TOP|| || | |C7TOP|| [[TJ-II:Lithium Beam|Lithium Beam]]|| | ||
|- | |- | ||
|C7SIDE|| || | |C7SIDE|| || | ||
|- | |- | ||
|C7BOT|| || | |C7BOT|| || | ||
|} | |||
=== Segment C8 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|C8TOP|| || | |C8TOP|| [[TJ-II:Helium Beam|Helium Beam]] || | ||
|- | |- | ||
|C8SIDE|| || | |C8SIDE|| [[TJ-II:Helium Beam|Helium Beam]] || | ||
|- | |- | ||
|C8BOT|| || | |C8BOT|| [[TJ-II:Helium Beam|Helium Beam]] || | ||
|- | |- | ||
|C8TANG|| || | |C8TANG|| || | ||
Line 165: | Line 279: | ||
== [[TJ-II:Sectors|Sector D]] == | == [[TJ-II:Sectors|Sector D]] == | ||
0 ≤ φ ≤ 90 ° | |||
=== Segment D1 === | |||
{| class="wikitable" align="center" border="1" | {| class="wikitable" align="center" border="1" | ||
!''Port'' !!''Diagnostic or device''!!''Comment'' | !''Port'' !!''Diagnostic or device''!!''Comment'' | ||
Line 175: | Line 292: | ||
|- | |- | ||
|D1TANG|| || | |D1TANG|| || | ||
|} | |||
=== Segment D2 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|D2TOP|| [[TJ-II:Thomson Scattering|Thomson Scattering]] (laser view dump) || | |D2TOP|| [[TJ-II:Thomson Scattering|Thomson Scattering]] (laser view dump) || | ||
|- | |- | ||
|D2SIDE|| [[TJ-II:Thomson Scattering|Thomson Scattering]] ( | |D2SIDE|| [[TJ-II:Thomson Scattering|Thomson Scattering]] (polychromator) || | ||
|- | |- | ||
|D2BOT|| [[TJ-II:Thomson Scattering|Thomson Scattering]] (laser entry)|| | |D2BOT|| [[TJ-II:Thomson Scattering|Thomson Scattering]] (laser entry)|| | ||
|} | |||
=== Segment D3 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|D3SIDE|| || | |D3SIDE|| || | ||
|- | |- | ||
|D3BOT|| || | |D3BOT|| || | ||
|} | |||
=== Segment D4 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|D4TOP|| || | |D4TOP|| [[TJ-II:Langmuir Probes|Langmuir probe]] || | ||
|- | |- | ||
|D4SIDE|| || | |D4SIDE|| || | ||
|- | |- | ||
|D4BOT|| || | |D4BOT|| || | ||
|} | |||
=== Segment D5 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|D5TOP|| || | |D5TOP|| || | ||
Line 197: | Line 334: | ||
|- | |- | ||
|D5BOT|| || | |D5BOT|| || | ||
|} | |||
=== Segment D6 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|D6TOP|| || | |D6TOP|| [[TJ-II:Electron_Bernstein_Wave_Heating|Bernstein Wave Heating]] (mirror) || | ||
|- | |- | ||
|D6SIDE|| || | |D6SIDE|| [[TJ-II:Electron_Bernstein_Wave_Heating|Bernstein Wave Heating]] || | ||
|} | |||
=== Segment D7 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|D7TOP|| || | |D7TOP|| || | ||
Line 207: | Line 354: | ||
|- | |- | ||
|D7BOT|| || | |D7BOT|| || | ||
|} | |||
=== Segment D8 === | |||
{| class="wikitable" align="center" border="1" | |||
!''Port'' !!''Diagnostic or device''!!''Comment'' | |||
|- | |- | ||
|D8TOP|| || | |D8TOP|| || | ||
|- | |- | ||
|D8SIDE|| || | |D8SIDE|| [[TJ-II:Spectroscopy|Spectroscopy]] (toroidal rotation) || | ||
|- | |- | ||
|D8BOT|| || | |D8BOT|| || |
Latest revision as of 14:24, 11 September 2018
The listing below specifies which diagnostics and devices are connected to each port of TJ-II.
Sector A
90 ≤ φ ≤ 180 °
Segment A1
Port | Diagnostic or device | Comment |
---|---|---|
A1TOP | ||
A1SIDE | ||
A1BOT | ||
A1TANG |
Segment A2
Port | Diagnostic or device | Comment |
---|---|---|
A2TOP | Soft X-ray tomography | |
A2SIDE | Soft X-ray tomography | |
A2BOT | Soft X-ray tomography |
Segment A3
Port | Diagnostic or device | Comment |
---|---|---|
A3SIDE | ||
A3BOT | Limiter |
Segment A4
Port | Diagnostic or device | Comment |
---|---|---|
A4TOP | AM reflectometer (profiles) Heavy Ion Beam Probe 2 (injection) |
|
A4SIDE | Heavy Ion Beam Probe 2 (spectrometer) | |
A4BOT |
Segment A5
Port | Diagnostic or device | Comment |
---|---|---|
A5TOP | Vacuum feedthrough connector for the A5 Rogowski coil and diamagnetic loop | |
A5SIDE | ||
A5BOT |
Segment A6
Port | Diagnostic or device | Comment |
---|---|---|
A6TOP | ||
A6SIDE | ECRH (QTL2) |
Segment A7
Port | Diagnostic or device | Comment |
---|---|---|
A7TOP | Biasing probe | |
A7SIDE | Charge exchange spectroscopy Diagnostic neutral beam |
|
A7BOT |
Segment A8
Port | Diagnostic or device | Comment |
---|---|---|
A8TOP | ||
A8SIDE | ||
A8BOT | ||
A8TANG |
Sector B
180 ≤ φ ≤ 270 °
Segment B1
Port | Diagnostic or device | Comment |
---|---|---|
B1TOP | ||
B1SIDE | ||
B1BOT | ||
B1TANG | Compact Neutral Particle Analyzer |
Segment B2
Port | Diagnostic or device | Comment |
---|---|---|
B2TOP | ||
B2SIDE | Pellet injector | |
B2BOT | Langmuir Probes |
Segment B3
Port | Diagnostic or device | Comment |
---|---|---|
B3SIDE | ECRH (QTL1) | |
B3BOT |
Segment B4
Port | Diagnostic or device | Comment |
---|---|---|
B4TOP | Heavy Ion Beam Probe 1 (injection) | |
B4SIDE | Heavy Ion Beam Probe 1 (spectrometer) Vacuum feedthrough connector for the B4 Rogowski coil and diamagnetic loop |
|
B4BOT |
Segment B5
Port | Diagnostic or device | Comment |
---|---|---|
B5TOP | Vacuum feedthrough connector for the second Mirnov coil straight vertical array | |
B5SIDE | ||
B5BOT |
Segment B6
Port | Diagnostic or device | Comment |
---|---|---|
B6TOP | ||
B6SIDE |
Segment B7
Port | Diagnostic or device | Comment |
---|---|---|
B7TOP | Multichannel Bolometry | |
B7SIDE | Multichannel Bolometry | |
B7BOT |
Segment B8
Port | Diagnostic or device | Comment |
---|---|---|
B8TOP | Microwave interferometer | |
B8SIDE | Spectroscopy (toroidal rotation) | |
B8BOT | Microwave interferometer | |
B8TANG | Fast camera |
Sector C
270 ≤ φ ≤ 360 °
Segment C1
Port | Diagnostic or device | Comment |
---|---|---|
C1TOP | ||
C1SIDE | ||
C1BOT | ||
C1TANG | NBI 1 |
Segment C2
Port | Diagnostic or device | Comment |
---|---|---|
C2TOP | ||
C2SIDE | ||
C2BOT |
Segment C3
Port | Diagnostic or device | Comment |
---|---|---|
C3SIDE | ||
C3BOT | Limiter |
Segment C4
Port | Diagnostic or device | Comment |
---|---|---|
C4TOP | Vacuum feedthrough connector for the first Mirnov coil straight vertical array | |
C4SIDE | ||
C4BOT |
Segment C5
Port | Diagnostic or device | Comment |
---|---|---|
C5TOP | ||
C5SIDE | ||
C5BOT |
Segment C6
Port | Diagnostic or device | Comment |
---|---|---|
C6TOP | Doppler Reflectometer (Mirror) | |
C6SIDE | Doppler Reflectometer (Antenna) |
Segment C7
Port | Diagnostic or device | Comment |
---|---|---|
C7TOP | Lithium Beam | |
C7SIDE | ||
C7BOT |
Segment C8
Port | Diagnostic or device | Comment |
---|---|---|
C8TOP | Helium Beam | |
C8SIDE | Helium Beam | |
C8BOT | Helium Beam | |
C8TANG |
Sector D
0 ≤ φ ≤ 90 °
Segment D1
Port | Diagnostic or device | Comment |
---|---|---|
D1TOP | ||
D1SIDE | ||
D1BOT | ||
D1TANG |
Segment D2
Port | Diagnostic or device | Comment |
---|---|---|
D2TOP | Thomson Scattering (laser view dump) | |
D2SIDE | Thomson Scattering (polychromator) | |
D2BOT | Thomson Scattering (laser entry) |
Segment D3
Port | Diagnostic or device | Comment |
---|---|---|
D3SIDE | ||
D3BOT |
Segment D4
Port | Diagnostic or device | Comment |
---|---|---|
D4TOP | Langmuir probe | |
D4SIDE | ||
D4BOT |
Segment D5
Port | Diagnostic or device | Comment |
---|---|---|
D5TOP | ||
D5SIDE | ||
D5BOT |
Segment D6
Port | Diagnostic or device | Comment |
---|---|---|
D6TOP | Bernstein Wave Heating (mirror) | |
D6SIDE | Bernstein Wave Heating |
Segment D7
Port | Diagnostic or device | Comment |
---|---|---|
D7TOP | ||
D7SIDE | ||
D7BOT |
Segment D8
Port | Diagnostic or device | Comment |
---|---|---|
D8TOP | ||
D8SIDE | Spectroscopy (toroidal rotation) | |
D8BOT | ||
D8TANG | NBI 2 |