<ref>[http://dx.doi.org/10.1002/ctpp.200410104 E. Calderón et al, ''On the Influence of Probe Presheath on the Measurement of Fluctuation and E × B Turbulent Transport by Langmuir Probes'', Contributions to Plasma Physics '''44''', Issue 7-8 (2004) 700 - 704]</ref> | <ref>[http://dx.doi.org/10.1002/ctpp.200410104 E. Calderón et al, ''On the Influence of Probe Presheath on the Measurement of Fluctuation and E × B Turbulent Transport by Langmuir Probes'', Contributions to Plasma Physics '''44''', Issue 7-8 (2004) 700 - 704]</ref> | ||
<ref>[http://link.aps.org/doi/10.1103/PhysRevLett.100.215003 M.A. Pedrosa et al, ''Evidence of Long-Distance Correlation of Fluctuations during Edge Transitions to Improved-Confinement Regimes in the TJ-II Stellarator'', Phys. Rev. Lett. '''100''' (2008) 215003]</ref> | <ref>[http://link.aps.org/doi/10.1103/PhysRevLett.100.215003 M.A. Pedrosa et al, ''Evidence of Long-Distance Correlation of Fluctuations during Edge Transitions to Improved-Confinement Regimes in the TJ-II Stellarator'', Phys. Rev. Lett. '''100''' (2008) 215003]</ref> | ||
Probe drive 1 is located at φ = 38° ([[TJ-II:Sectors|sector]] D4) and probe drive 2 at φ = 195° ([[TJ-II:Sectors|sector]] B2). | Probe drive 1 is located at φ = 38.2°, R=134 cm ([[TJ-II:Sectors|sector]] D4) and probe drive 2 at φ = 195° ([[TJ-II:Sectors|sector]] B2). | ||
== Probe heads == | == Probe heads == |
Revision as of 10:43, 22 October 2014
TJ-II has two fast reciprocating drives for Langmuir probes (with a displacement velocity of approximately 1 m/s). [1] [2] [3] Probe drive 1 is located at φ = 38.2°, R=134 cm (sector D4) and probe drive 2 at φ = 195° (sector B2).
Probe heads
Several different heads can be mounted on the reciprocating drives: e.g., staircase Langmuir probes, a rake probe (as of 2009), or a multi-pin Langmuir probe (2010). A biasing probe has also been used.
See also
References
- ↑ M.A. Pedrosa et al, Fast movable remotely controlled Langmuir probe system, Rev. Sci. Instrum. 70 (1999) 415
- ↑ E. Calderón et al, On the Influence of Probe Presheath on the Measurement of Fluctuation and E × B Turbulent Transport by Langmuir Probes, Contributions to Plasma Physics 44, Issue 7-8 (2004) 700 - 704
- ↑ M.A. Pedrosa et al, Evidence of Long-Distance Correlation of Fluctuations during Edge Transitions to Improved-Confinement Regimes in the TJ-II Stellarator, Phys. Rev. Lett. 100 (2008) 215003