(Created page with "The OLMAT (Optimization of liquid targets) facility at the Laboratorio Nacional de Fusión is aimed at testing LM (Liquid Metal) prototypes under DEMO-relevant heat loads <ref>Alegre D., Oyarzabal E., Tafalla D., Liniers M., Soleto A. and Tabarés F.L. (2020) ''Design and testing of advanced liquid metal targets for DEMO divertor: the OLMAT project''. J. Fusion Energy 39 411</ref>. File:OLMAT.jpg|400px|thumb|right|CAD design of...")
 
No edit summary
 
Line 1: Line 1:
The OLMAT (Optimization of liquid targets) facility at the [[Laboratorio Nacional de Fusión]] is aimed at testing LM (Liquid Metal) prototypes under DEMO-relevant heat loads <ref>Alegre D., Oyarzabal E., Tafalla D., Liniers M., Soleto A. and Tabarés F.L. (2020) ''Design and testing of advanced liquid metal targets for DEMO divertor: the OLMAT project''. [[doi:10.1007/s10894-020-00254-5|J. Fusion Energy 39 411]]</ref>.  
The OLMAT (Optimization of Liquid Metal Targets) facility at the [[Laboratorio Nacional de Fusión]] is aimed at testing LM (Liquid Metal) prototypes under DEMO-relevant heat loads <ref>Alegre D., Oyarzabal E., Tafalla D., Liniers M., Soleto A. and Tabarés F.L. (2020) ''Design and testing of advanced liquid metal targets for DEMO divertor: the OLMAT project''. [[doi:10.1007/s10894-020-00254-5|J. Fusion Energy 39 411]]</ref>.  


[[File:OLMAT.jpg|400px|thumb|right|CAD design of OLMAT. (a) irradiation chamber; (b) valve to NBI; (c) valve to TJ-II; (d) pre-chamber for sample loading; (e) sample insertion system; (f) upper turbopump with liquid metal condensation bafflers; (g) BaF2 optical window for infrared thermography; (h) diagnostic ports and windows.]]
[[File:OLMAT.jpg|400px|thumb|right|CAD design of OLMAT. (a) irradiation chamber; (b) valve to NBI; (c) valve to TJ-II; (d) pre-chamber for sample loading; (e) sample insertion system; (f) upper turbopump with liquid metal condensation bafflers; (g) BaF2 optical window for infrared thermography; (h) diagnostic ports and windows.]]
Line 7: Line 7:
Moreover, the NBI beam is wide enough to irradiate large samples (<20 cm diameter), allowing redeposition studies of the eroded and evaporated material.  
Moreover, the NBI beam is wide enough to irradiate large samples (<20 cm diameter), allowing redeposition studies of the eroded and evaporated material.  
In a second stage of the project a Q-CW, high-power fibre laser is used to simulate ELM-like powers in a small area, or the strike point power deposition profile.
In a second stage of the project a Q-CW, high-power fibre laser is used to simulate ELM-like powers in a small area, or the strike point power deposition profile.
[[File:OLMAT1.png|500px|thumb|center|The OLMAT facility and TJ-II]]


== References ==
== References ==
<references />
<references />