TJ-II is fitted with an ample set of Mirnov coils: | TJ-II is fitted with an ample set of Mirnov coils: | ||
<ref>[http://www.new.ans.org/pubs/journals/fst/a_1283 R. Jiménez-Gómez et al., Fusion Science and Technology '''51''', 20 (2007)]</ref> | <ref>[http://www.new.ans.org/pubs/journals/fst/a_1283 R. Jiménez-Gómez et al., Fusion Science and Technology '''51''', 20 (2007)]</ref> | ||
* Two straight arrays above the plasma column, each with 12 coils, mounted in a 0.5 mm thick stainless steel tube attached to a port flange. The 12 coils are distributed in 4 groups of 3 coils each, separated by a distance of 30 mm. The three coils in each group measure the three cylindrical components (''R'', ''Z'', and ''φ'') of the magnetic field. They are located in [[TJ-II:Sectors|sectors]] B5 and C4, at ''φ'' = 232 and 308 | * Two straight arrays above the plasma column, each with 12 coils, mounted in a 0.5 mm thick stainless steel tube attached to a port flange. The 12 coils are distributed in 4 groups of 3 coils each, separated by a distance of 30 mm. The three coils in each group measure the three cylindrical components (''R'', ''Z'', and ''φ'') of the magnetic field. They are located in [[TJ-II:Sectors|sectors]] B5 and C4, at ''φ'' = 232° and 308°. | ||
* One poloidal array with 15 coils measuring the poloidal field component. This array is located between [[TJ-II:Sectors|sectors]] D4 and D5, at ''φ'' = 45 | * One poloidal array with 15 coils measuring the poloidal field component. This array is located between [[TJ-II:Sectors|sectors]] D4 and D5, at ''φ'' = 45°. | ||
== Rogowski coils == | == Rogowski coils == | ||
Two Rogowski coils have been installed in [[TJ-II:Sectors|sectors]] A5 (148.7°) and B4 (211.3°) | Two Rogowski coils have been installed in [[TJ-II:Sectors|sectors]] A5 (148.7°) and B4 (211.3°). Since the coils have to surround the plasma column completely, they are located under the protecting tiles of the groove that runs toroidally all along the [[TJ-II:Vacuum system|vacuum vessel]]. For this purpose, 2 mm deep channels were machined on the vacuum side of the groove, at the above mentioned poloidal cross sections, in order to allow enough space for the coils. | ||
The signals 'Ip_a5_' and 'Ip_b4_' in the [[TJ-II:Shot database|TJ-II database]] provide the corresponding measurements of the net plasma current. | The signals 'Ip_a5_' and 'Ip_b4_' in the [[TJ-II:Shot database|TJ-II database]] provide the corresponding measurements of the net plasma current. |