TJ-II:Magnetics: Difference between revisions

From FusionWiki
Jump to navigation Jump to search
Line 16: Line 16:
[[File:TJ-II_Diamagnetic_loop.jpg|200px|thumb|left|TJ-II diamagnetic loop]]
[[File:TJ-II_Diamagnetic_loop.jpg|200px|thumb|left|TJ-II diamagnetic loop]]


Two internal diamagnetic loops are installed at φ = 135º and 225º.
Two internal diamagnetic loops are installed at φ = 135º ([[TJ-II:Sectors|sector]] B4) and 225º ([[TJ-II:Sectors|sector]] C4).
They consist of a main loop which encircles the plasma column
They consist of a main loop which encircles the plasma column
and runs under the protecting tiles in the groove region and a compensating loop which
and runs under the protecting tiles in the groove region and a compensating loop which
measures only the vacuum magnetic flux.
measures only the vacuum magnetic flux.
The signal 'W_b4_corr' in the [[TJ-II:Shot database|TJ-II database]] returns the energy content of the plasma, based on the diamagnetic loop in [[TJ-II:Sectors|sector]] B4, corrected for the net plasma current.


== References ==
== References ==
<references />
<references />

Revision as of 09:24, 3 November 2009

Mirnov coils

The poloidal array of Mirnov coils at TJ-II

TJ-II is fitted with an ample set of Mirnov coils: [1]

  • Two straight arrays above the plasma column, each with 12 coils, mounted in a 0.5 mm thick stainless steel tube attached to a port flange. The 12 coils are distributed in 4 groups of 3 coils each, separated by a distance of 30 mm. The three coils in each group measure the three cylindrical components (R, Z, and φ) of the magnetic field. They are located in sectors B5 and C4, at φ = 142 and 218 degrees.
  • One poloidal array with 15 coils measuring the poloidal field component. This array is located between sectors D4 and D5, at φ = 315 degrees.

Rogowski coils

Two Rogowski coils have been installed in sectors A5 (148.7°) and B4 (211.3°). Since the coils have to surround the plasma column completely, they are located under the protecting tiles of the groove that runs toroidally all along the vacuum vessel. For this purpose, 2 mm deep channels were machined on the vacuum side of the groove, at the above mentioned poloidal cross sections, in order to allow enough space for the coils.

Diamagnetic loops

TJ-II diamagnetic loop

Two internal diamagnetic loops are installed at φ = 135º (sector B4) and 225º (sector C4). They consist of a main loop which encircles the plasma column and runs under the protecting tiles in the groove region and a compensating loop which measures only the vacuum magnetic flux.

The signal 'W_b4_corr' in the TJ-II database returns the energy content of the plasma, based on the diamagnetic loop in sector B4, corrected for the net plasma current.

References