TJ-II:Bolometry: Difference between revisions

From FusionWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(7 intermediate revisions by 2 users not shown)
Line 1: Line 1:
[[File:TJ-II_Bolometer.png|400px|thumb|right|The TJ-II bolometry system for tomographic reconstruction (sector B7)]]
[[File:TJ-II_Bolometer.png|400px|thumb|right|The TJ-II bolometry system for tomographic reconstruction ([[TJ-II:Sectors|sector]] B7, φ = 255.5 °)]]


TJ-II has several bolometry systems
TJ-II has several bolometry systems
<ref>[http://www.new.ans.org/pubs/journals/fst/a_1252 M.A. Ochando et al., Fusion Sci. Technol. '''50''', 313 (2006)]</ref>
<ref>M.A. Ochando et al., ''Up-Down and In-Out Asymmetry Monitoring Based on Broadband Radiation Detectors'', [http://www.new.ans.org/pubs/journals/fst/a_1252 Fusion Sci. Technol. '''50''', 313 (2006)]</ref>
<ref>B. Zurro et al, ''Method to deduce local impurity transport quantities from the evolution of tomographically reconstructed bolometer signals during tracer injection at TJ-II'', [[doi:10.1063/1.1787585|Rev. Sci. Instrum. '''75''' (2004) 4231]]</ref>
:
:
* Three 20-channel pinhole cameras in [[TJ-II:Sectors|sector]] B7, monitoring the same poloidal section and used for tomographic reconstructions <ref>[[EBITA]]</ref> of the total plasma emissivity. Signal names in the [[TJ-II:Shot_database|TJ-II database]]: 'BO101' ... 'BO120', 'BO201' ... 'BO220', 'BO301' ... 'BO320'.
* Three 20-channel pinhole cameras in [[TJ-II:Sectors|sector]] B7, monitoring the same poloidal section and used for tomographic reconstructions <ref>[[EBITA]]</ref><ref>[[TJ-II:Tomography]]</ref> of the total plasma emissivity. <ref>E. Barrera et al, ''Real-time data acquisition and parallel data processing solution for TJ-II Bolometer arrays diagnostic'', [[doi:10.1016/j.fusengdes.2006.04.046|Fusion Engineering and Design '''81''', Issues 15-17 (2006) 1863-1867]]</ref> Signal names in the [[TJ-II:Shot_database|TJ-II database]]: 'BO101' ... 'BO120', 'BO201' ... 'BO220', 'BO301' ... 'BO320'.
* Three 16-channel cameras in [[TJ-II:Sectors|sectors]] A2, C2, D2. Signal names in the [[TJ-II:Shot_database|TJ-II database]]: 'ABOL1' ... 'ABOL16', 'CBOL1' ... 'CBOL16', 'DBOL1' ... 'DBOL16'.  
* Three 16-channel cameras in [[TJ-II:Sectors|sectors]] A7, C2, D7. Signal names in the [[TJ-II:Shot_database|TJ-II database]]: 'ABOL1' ... 'ABOL16', 'CBOL1' ... 'CBOL16', 'DBOL1' ... 'DBOL16'.  
* Six global bolometry monitors. Signal names in the [[TJ-II:Shot_database|TJ-II database]]: 'BOL1', 'BOL3', 'BOL6'; 'BOL2', 'BOL5', 'BOL7'.
* Six global bolometry monitors. Signal names in the [[TJ-II:Shot_database|TJ-II database]]: 'BOL1', 'BOL3', 'BOL6'; 'BOL2', 'BOL5', 'BOL7'.


==References==
==References==
<references />
<references />

Latest revision as of 16:36, 29 October 2015

The TJ-II bolometry system for tomographic reconstruction (sector B7, φ = 255.5 °)

TJ-II has several bolometry systems [1] [2]

  • Three 20-channel pinhole cameras in sector B7, monitoring the same poloidal section and used for tomographic reconstructions [3][4] of the total plasma emissivity. [5] Signal names in the TJ-II database: 'BO101' ... 'BO120', 'BO201' ... 'BO220', 'BO301' ... 'BO320'.
  • Three 16-channel cameras in sectors A7, C2, D7. Signal names in the TJ-II database: 'ABOL1' ... 'ABOL16', 'CBOL1' ... 'CBOL16', 'DBOL1' ... 'DBOL16'.
  • Six global bolometry monitors. Signal names in the TJ-II database: 'BOL1', 'BOL3', 'BOL6'; 'BOL2', 'BOL5', 'BOL7'.

References

  1. M.A. Ochando et al., Up-Down and In-Out Asymmetry Monitoring Based on Broadband Radiation Detectors, Fusion Sci. Technol. 50, 313 (2006)
  2. B. Zurro et al, Method to deduce local impurity transport quantities from the evolution of tomographically reconstructed bolometer signals during tracer injection at TJ-II, Rev. Sci. Instrum. 75 (2004) 4231
  3. EBITA
  4. TJ-II:Tomography
  5. E. Barrera et al, Real-time data acquisition and parallel data processing solution for TJ-II Bolometer arrays diagnostic, Fusion Engineering and Design 81, Issues 15-17 (2006) 1863-1867