TJ-II:Biasing probe

Revision as of 15:03, 21 September 2010 by Admin (talk | contribs)

At TJ-II, a 2-D carbon composite mushroom shaped electrode (12 mm high with a diameter of 25 mm) has been developed and installed on a fast reciprocating probe drive. Typically, the electrode is inserted to a position 2 cm inside the last closed flux surface (LCFS) and biased positively (200-300 V) with respect to one of the two TJ-II limiters located in the scrape-off layer region (about 0.5 cm beyond the LCFS). Measured electrode currents are in the range of 30-50 A. [1] [2]

Layout of the biasing probe, mounted on the reciprocating probe drive

In 2009, the power source (originally DC) has been upgraded to allow modulation with a frequency of up to a few kHz.

Location: sector A4. Signal names in the TJ-II database: 'PolI', 'PolV'.

Photo of the reciprocating drive of the biasing probe (top right)

References