TJ-II:Thomson Scattering: Difference between revisions

Jump to navigation Jump to search
Updated reference links
No edit summary
(Updated reference links)
 
Line 4: Line 4:
(located in [[TJ-II:Sectors|sector]] D2, φ = 14.5°)
(located in [[TJ-II:Sectors|sector]] D2, φ = 14.5°)
provides electron temperature, density, and pressure profiles at a single time in the discharge.
provides electron temperature, density, and pressure profiles at a single time in the discharge.
<ref>[http://link.aip.org/link/?RSINAK/70/763/1 C.J. Barth et al, ''High-resolution multiposition Thomson scattering for the TJ-II stellarator'', Rev. Sci. Instruments, Vol. '''70''', 1 (1999) 763-767]</ref>
<ref>C.J. Barth et al, ''High-resolution multiposition Thomson scattering for the TJ-II stellarator'', [[doi:10.1063/1.1149399|Rev. Sci. Instruments, Vol. '''70''', 1 (1999) 763-767]]</ref>
<ref>[http://link.aps.org/doi/10.1103/PhysRevLett.85.4715 J. Herranz, I. Pastor, F. Castejón, E. de la Luna, I. García-cortés, C.J. Barth, E. Ascasíbar, J. Sánchez, and V. Tribaldos, ''Profile structures of TJ-II stellarator plasmas'', Phys. Rev. Lett. '''85''' (2000) 4715]</ref>
<ref>J. Herranz, I. Pastor, F. Castejón, E. de la Luna, I. García-Cortés, C.J. Barth, E. Ascasíbar, J. Sánchez, and V. Tribaldos, ''Profile structures of TJ-II stellarator plasmas'', [[doi:10.1103/PhysRevLett.85.4715|Phys. Rev. Lett. '''85''' (2000) 4715]]</ref>
<ref>[http://link.aip.org/link/?RSINAK/72/3514/1 C.J. Barth et al, ''Calibration procedure and data processing for a TV Thomson scattering system'', Rev. Sci. Instruments, Vol. '''72''', 9 (2001) 3514-3527]</ref>
<ref>C.J. Barth et al, ''Calibration procedure and data processing for a TV Thomson scattering system'', [[doi:10.1063/1.1386896|Rev. Sci. Instruments, Vol. '''72''', 9 (2001) 3514-3527]]</ref>
<ref>J. Herranz et al. ''Analysis of the Detection Process and Error Sources for the Thomson Scattering Profile Measurement in TJ-II''. Proc. issues of the 14th Topical Conf. on High Temperature Plasma Diagnostics, A.P.S., July 8, 2002, Madison, WI</ref>
<ref>J. Herranz et al. ''Analysis of the Detection Process and Error Sources for the Thomson Scattering Profile Measurement in TJ-II''. Proc. issues of the 14th Topical Conf. on High Temperature Plasma Diagnostics, A.P.S., July 8, 2002, Madison, WI</ref>
<ref>[http://dx.doi.org/10.1016/S0920-3796(03)00387-9 J. Herranz et al, ''The spectrometer of the high-resolution multiposition Thomson scattering diagnostic for TJ-II'', Fus. Eng. And Design, '''65''' (2003) 525-536]</ref>
<ref>J. Herranz et al, ''The spectrometer of the high-resolution multiposition Thomson scattering diagnostic for TJ-II'', [[doi:10.1016/S0920-3796(03)00387-9|Fus. Eng. And Design, '''65''' (2003) 525-536]]</ref>
<ref>[http://link.aip.org/link/?RSINAK/74/3998/1 B.Ph. van Milligen et al, ''Revision of TV Thomson scattering data analysis and detection of profile structure'', Rev. Sci. Instrum. '''74''' (2003) 3998]</ref>
<ref>B.Ph. van Milligen et al, ''Revision of TV Thomson scattering data analysis and detection of profile structure'', [[doi:10.1063/1.1597951|Rev. Sci. Instrum. '''74''' (2003) 3998]]</ref>
The laser chord is inclined by 17&deg; from the vertical.
The laser chord is inclined by 17&deg; from the vertical.


Line 34: Line 34:


Some progress has also been made in the field of data analysis.
Some progress has also been made in the field of data analysis.
<ref>[[doi:10.1016/j.fusengdes.2009.10.004|L. Makili, J. Vega, S. Dormido-Canto, et al., ''Upgrade of the automatic analysis system in the TJ-II Thomson Scattering diagnostic: New image recognition classifier and fault condition detection'', Fusion Engineering and Design '''85''' (2010) 415–418]]</ref>
<ref>L. Makili, J. Vega, S. Dormido-Canto, et al., ''Upgrade of the automatic analysis system in the TJ-II Thomson Scattering diagnostic: New image recognition classifier and fault condition detection'', [[doi:10.1016/j.fusengdes.2009.10.004|Fusion Engineering and Design '''85''' (2010) 415–418]]</ref>
<ref>[[doi:10.1016/j.fusengdes.2012.04.004|S. Dormido-Canto, G. Farias, J. Vega, I. Pastor, ''Image processing methods for noise reduction in the TJ-II Thomson Scattering diagnostic'', Fusion Engineering and Design (2012)]]</ref>
<ref>S. Dormido-Canto, G. Farias, J. Vega, I. Pastor, ''Image processing methods for noise reduction in the TJ-II Thomson Scattering diagnostic'', [[doi:10.1016/j.fusengdes.2012.04.004|Fusion Engineering and Design (2012)]]</ref>


== References ==
== References ==
<references />
<references />

Navigation menu