4,422
edits
m (Reverted edits by 182.23.159.34 (Talk) to last revision by Admin) |
(Updated reference links) |
||
Line 18: | Line 18: | ||
The double wavelength heterodyne interferometer (CO<sub>2</sub>: 10.6 μm, NdYAG: 1.064 μm) | The double wavelength heterodyne interferometer (CO<sub>2</sub>: 10.6 μm, NdYAG: 1.064 μm) | ||
provides values of the plasma line integral density in scenarios with average densities ranging from a few times 10<sup>18</sup> m<sup>–3</sup> to more than 5×10<sup>19</sup> m<sup>–3</sup>. The results have been compared with those from the 2 mm (microwave) interferometer, obtaining an excellent agreement. Working with a final bandwidth of 4 kHz, a one pass line integral error level about ±2×10<sup>17</sup> m<sup>–2</sup> has been achieved. | provides values of the plasma line integral density in scenarios with average densities ranging from a few times 10<sup>18</sup> m<sup>–3</sup> to more than 5×10<sup>19</sup> m<sup>–3</sup>. The results have been compared with those from the 2 mm (microwave) interferometer, obtaining an excellent agreement. Working with a final bandwidth of 4 kHz, a one pass line integral error level about ±2×10<sup>17</sup> m<sup>–2</sup> has been achieved. | ||
<ref> | <ref>H. Lamela et al, ''Laser interferometric experiments for the TJ-II stellarator electron-density measurements'', [[doi: 10.1063/1.1333040|Rev. Sci. Instrum. '''72''' (2001) 96]]</ref> | ||
<ref> | <ref>M. Sánchez at al, ''High resolution CO<sub>2</sub> interferometry on the TJ-II stellarator by using an ADC-based phase meter'', [[doi:10.1063/1.1786638|Rev. Sci. Instrum. '''75''' (2004) 3414]]</ref> | ||
<ref> | <ref>P. Acedo et al, ''CO<sub>2</sub> (λ<sub>m</sub> = 10.6 μm) He–Ne (λ<sub>c</sub> = 633 nm) two-color laser interferometry for low and medium electron density measurements in the TJ-II Stellarator'', [[doi:10.1063/1.1809283|Rev. Sci. Instrum. '''75''', 11 (2004) 4671]]</ref> | ||
<ref> | <ref>M. Sánchez et al, ''Admissible Crosstalk Limits in a Two Colour Interferometers for Plasma Density Diagnostics. A Reduction Algorithm'', PLASMA 2007, [[doi:10.1063/1.2909105|AIP Conf. Proc. '''993''' (2008) 187-190]]</ref> | ||
<ref> | <ref>P. Acedo et al, ''Calibration of a high spatial resolution laser two-color heterodyne interferometer for density profile measurements in the TJ-II stellarator'', [[doi:10.1063/1.2973326|Rev. Sci. Instrum. '''79''' (2008) 10E713]]</ref> | ||
<ref> | <ref>L. Esteban, M. Sánchez, J.A. López, O. Nieto-Taladriz and J. Sánchez, ''Continuous plasma density measurement in TJ-II infrared interferometer—Advanced signal processing based on FPGAs'', [[doi:10.1016/j.fusengdes.2010.03.036|Fus. Eng. Design '''85''', 3-4 (2010) 328]]</ref> | ||
<ref> | <ref>P. Pedreira, L. Esteban, A.R. Criado, P. Acedo, M. Sánchez, and J. Sánchez, ''Two color multichannel heterodyne interferometer set up for high spatial resolution electron density profile measurements in TJ-II'', [[doi:10.1063/1.3475729|Rev. Sci. Instrum. '''81''' (2010) 10D517]]</ref> | ||
The system is located in [[TJ-II:Sectors|sector]] B1. | The system is located in [[TJ-II:Sectors|sector]] B1. | ||
==References== | ==References== | ||
<references /> | <references /> |