Until now, only ECCD on-axis has been investigated. We will now try to modify the rotational transform profile by inducing ECCD off-axis with  
Until now, only ECCD on-axis has been investigated. We will now try to modify the rotational transform profile by inducing ECCD off-axis with  
different levels of power at different plasma radius. The heating power set-up shown in figure 1 will allow  
different levels of power at different plasma radius. The heating power set-up shown in figure 1 will allow  
us to investigate the effect of ECCD with different combinations of ECH1 beam power and ECCD efficiency.   
us to investigate the effect of ECCD using different combinations of ECH1 beam power and ECCD efficiency.   
With this set-up, lauching ECH2 power with <math>n_{||}=0</math> , only a small amount of ECCD current will be induced during the ECRH phase  
With this set-up, launching ECH2 power with <math>n_{||}=0</math> , only a small amount of ECCD current will be induced by the
while the larger amount of ECCD generated by ECH1 beam will be induced during the NBI phase. For stability purposes ECH1 must be working at low power from the begginning of the shot until higher power is requested.
ECH1 beam during the ECRH phase while the larger amount of ECCD will be induced during the NBI phase by increasing the ECH1 beam power. For stability purposes ECH1 must be working at low power from the begginning of the shot until higher power is requested.


== Description of required resources ==
== Description of required resources ==
Line 41: Line 41:
* Essential diagnostic systems: Besides the common shot to shot diagnostics (ECE, Thomson, Interferometry, Radiation), all systems providing edge plasma profiles are needed. Moreover, HIBP, Doppler Reflectometer, Mirnov coils (both helicoidal and poloidal arrays) and CNPA meaurements are mandatory. MSE would also be desirable to measure changes induced by ECCD.   
* Essential diagnostic systems: Besides the common shot to shot diagnostics (ECE, Thomson, Interferometry, Radiation), all systems providing edge plasma profiles are needed. Moreover, HIBP, Doppler Reflectometer, Mirnov coils (both helicoidal and poloidal arrays) and CNPA meaurements are mandatory. MSE would also be desirable to measure changes induced by ECCD.   
* Type of plasmas (heating configuration): ECRH + NBI-1 hydrogen plasmas following the heating scheme shown in Figure 1.
* Type of plasmas (heating configuration): ECRH + NBI-1 hydrogen plasmas following the heating scheme shown in Figure 1.
* Specific requirements on wall conditioning if any:
* External users: need a local computer account for data access: yes/no
* Any external equipment to be integrated? Provide description and integration needs:


== Preferred dates and degree of flexibility ==
== Preferred dates and degree of flexibility ==
Line 49: Line 46:
of the proposal submission
of the proposal submission


(format dd-mm-yyyy)
 