TJ-II:Shot database: Difference between revisions

From FusionWiki
Jump to navigation Jump to search
(Created page with 'Raw data and data with minimal processing are stored in the TJ-II Shot Database, which allows storing both time traces and spatial profiles. Selected data (at low time resolution…')
 
 
(20 intermediate revisions by 7 users not shown)
Line 1: Line 1:
Raw data and data with minimal processing are stored in the TJ-II Shot Database, which allows storing both time traces and spatial profiles. Selected data (at low time resolution) and processed data are stored in the TJ-II Relational Database.  
Raw data and data with minimal processing are stored in the TJ-II Shot Database, which allows storing both time traces and spatial profiles.  


The documents referred to in the following are available on-line
Raw data are stored in the database as soon as the data acquisition process of a [[TJ-II]] discharge is finished.
[http://www-fusion.ciemat.es/cgi-bin/dir/dirnew.cgi?manuals/Databases_TJII/ here] (internal access only).
Relevant accompanying factors (e.g., calibration constants, offsets) can be stored with the data. After storage, the raw data cannot be modified.
 
Processed data can be incorporated at any time after the discharge, and can be overwritten if needed. The signal names of processed data terminate in an underscore.


== Documentation ==
== Documentation ==


* General information about the TJ-II Shot Database<ref>[http://dx.doi.org/10.1016/S0920-3796(00)00133-2 J. Vega, C. Crémy, E. Sánchez, A. Portas, J. A. Fábregas, R. Herrera. Data management in the TJ-II multi-layer database. Fus. Eng. and Design, '''48''' (2000) 69-79]</ref>
The documents referred to below are available on-line
* [http://fudaqs2.ciemat.es/TJ2WEB/AyudaDatos/index.htm The software library for accessing the raw data]<ref>[http://link.aip.org/link/?RSINAK/70/498/1 J. Vega, E. Sánchez, C. Crémy, A. Portas, C. M. Dulya, J. Nilsson. TJ-II data retrieving by means of a client/server model. Rev. Sci. Instr. '''70''':1 (1999) 498]</ref>
[http://www-fusion.ciemat.es/cgi-bin/dir/dirnew.cgi?manuals/Databases_TJII/ here] (internal laboratory access only).
* The Remote Procedure Call (RPC) library for accessing data<ref>[http://link.aip.org/link/?RSINAK/72/525/1 E. Sánchez, J. Vega, C. Crémy and A. Portas. Accessing TJ-II data with remote procedure call. Rev. Sci. Instr., '''72'''(1) (2001) 525-529]</ref>
 
* General information about the TJ-II Shot Database<ref>J. Vega, C. Crémy, E. Sánchez, A. Portas, J. A. Fábregas, R. Herrera, ''Data management in the TJ-II multi-layer database'', [[doi:10.1016/S0920-3796(00)00133-2|Fus. Eng. and Design '''48''' (2000) 69-79]]</ref>
* [http://fudaqs2.ciemat.es/TJ2WEB/AyudaDatos/index.htm The software library for accessing the raw data]<ref>J. Vega, E. Sánchez, C. Crémy, A. Portas, C. M. Dulya, J. Nilsson, ''TJ-II data retrieving by means of a client/server model'', [[doi:10.1063/1.1149283|Rev. Sci. Instr. '''70''' (1) (1999) 498]]</ref>
* The Remote Procedure Call (RPC) library for accessing data<ref>E. Sánchez, J. Vega, C. Crémy and A. Portas, ''Accessing TJ-II data with remote procedure call'', [[doi:10.1063/1.1316757|Rev. Sci. Instr. '''72''' (1) (2001) 525-529]]</ref>
* Data access interface routines for MatLab: [http://intranet-fusion.ciemat.es/ Intranet, National Fusion Laboratory (CIEMAT)] / Document Server / Manuals and Software / Matlab acceso datos TJ-II
 
== See also ==
 
* [[TJ-II:Relational database|TJ-II Relational database]]
* [[MDSplus]]


== References ==
== References ==
<references />
<references />

Latest revision as of 17:34, 11 March 2021

Raw data and data with minimal processing are stored in the TJ-II Shot Database, which allows storing both time traces and spatial profiles.

Raw data are stored in the database as soon as the data acquisition process of a TJ-II discharge is finished. Relevant accompanying factors (e.g., calibration constants, offsets) can be stored with the data. After storage, the raw data cannot be modified.

Processed data can be incorporated at any time after the discharge, and can be overwritten if needed. The signal names of processed data terminate in an underscore.

Documentation

The documents referred to below are available on-line here (internal laboratory access only).

See also

References

  1. J. Vega, C. Crémy, E. Sánchez, A. Portas, J. A. Fábregas, R. Herrera, Data management in the TJ-II multi-layer database, Fus. Eng. and Design 48 (2000) 69-79
  2. J. Vega, E. Sánchez, C. Crémy, A. Portas, C. M. Dulya, J. Nilsson, TJ-II data retrieving by means of a client/server model, Rev. Sci. Instr. 70 (1) (1999) 498
  3. E. Sánchez, J. Vega, C. Crémy and A. Portas, Accessing TJ-II data with remote procedure call, Rev. Sci. Instr. 72 (1) (2001) 525-529