TJ-II:Interferometry

From FusionWiki
Revision as of 12:05, 15 July 2009 by Admin (talk | contribs) (Created page with 'TJ-II has two interferometry systems. == The Microwave interferometer == The probing beam has a frequency of 140 GHz, corresponding to a wavelength of <math>\lambda</math> = 2.…')
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

TJ-II has two interferometry systems.

The Microwave interferometer

The probing beam has a frequency of 140 GHz, corresponding to a wavelength of = 2.14 mm. The diagnostic provides a time trace of the-line integrated electron density (65536 points, sampling rate 100 kHz). The signal is less reliable for high densities (above ). This time trace is fundamental for machine operation.

The CO2 interferometer

The probing wavelength is about .