The double wavelength heterodyne interferometer (CO<sub>2</sub>: 10.6 &mu;m, HeNe: 0.63 &mu;m)  
The double wavelength heterodyne interferometer (CO<sub>2</sub>: 10.6 &mu;m, HeNe: 0.63 &mu;m)  
provides values of the plasma line integral density in scenarios with average densities ranging from a few times 10<sup>18</sup> m<sup>–3</sup> to more than 5&times;10<sup>19</sup> m<sup>–3</sup>. The results have been compared with those from the 2 mm (microwave) interferometer, obtaining an excellent agreement. Working with a final bandwidth of 4 kHz, a one pass line integral error level about 2&times;10<sup>17</sup> m<sup>–2</sup> has been achieved.
provides values of the plasma line integral density in scenarios with average densities ranging from a few times 10<sup>18</sup> m<sup>–3</sup> to more than 5&times;10<sup>19</sup> m<sup>–3</sup>. The results have been compared with those from the 2 mm (microwave) interferometer, obtaining an excellent agreement. Working with a final bandwidth of 4 kHz, a one pass line integral error level about &plusmn;2&times;10<sup>17</sup> m<sup>–2</sup> has been achieved.
<ref>[http://link.aip.org/link/?RSINAK/72/96/1 H. Lamela et al,  ''Laser interferometric experiments for the TJ-II stellarator electron-density measurements'', Rev. Sci. Instrum. '''72''', 96 (2001)]</ref>
<ref>[http://link.aip.org/link/?RSINAK/72/96/1 H. Lamela et al,  ''Laser interferometric experiments for the TJ-II stellarator electron-density measurements'', Rev. Sci. Instrum. '''72''', 96 (2001)]</ref>
<ref>[http://link.aip.org/link/?RSINAK/75/3414/1 M. Sánchez at al, ''High resolution CO<sub>2</sub> interferometry on the TJ-II stellarator by using an ADC-based phase meter'', Rev. Sci. Instrum. '''75''', 3414 (2004)]</ref>
<ref>[http://link.aip.org/link/?RSINAK/75/3414/1 M. Sánchez at al, ''High resolution CO<sub>2</sub> interferometry on the TJ-II stellarator by using an ADC-based phase meter'', Rev. Sci. Instrum. '''75''', 3414 (2004)]</ref>

Revision as of 19:21, 25 September 2009

TJ-II has two interferometry systems for the measurement of the line-integrated density.

The Microwave interferometer

The diagnostic is located in sector B8. The probing beam has an inclination of 18.7º with respect to the vertical and a frequency of 140 GHz, corresponding to a wavelength of λ = 2.14 mm. The diagnostic provides a time trace of the line-integrated electron density (65536 points, sampling rate 100 kHz). The time trace is called 'Densidad2_' in the TJ-II database. The signal is less reliable for high densities (above 2-3 1019 m-3). This time trace is fundamental for machine operation.

Two-colour interferometer

The double wavelength heterodyne interferometer (CO2: 10.6 μm, HeNe: 0.63 μm) provides values of the plasma line integral density in scenarios with average densities ranging from a few times 1018 m–3 to more than 5×1019 m–3. The results have been compared with those from the 2 mm (microwave) interferometer, obtaining an excellent agreement. Working with a final bandwidth of 4 kHz, a one pass line integral error level about ±2×1017 m–2 has been achieved. [1] [2] The system is located in sector B1.

References