by means of a 16 channel heterodyne radiometer,
by means of a 16 channel heterodyne radiometer,
covering the frequency range 50–60 GHz, corresponding to the second harmonic of electron cyclotron emission (ECE) in X-mode polarization at a magnetic field of 0.95 T on the plasma axis.  
covering the frequency range 50–60 GHz, corresponding to the second harmonic of electron cyclotron emission (ECE) in X-mode polarization at a magnetic field of 0.95 T on the plasma axis.  
The measurements are performed from the low field side (LFS) in the horizontal midplane ([[TJ-II:Sectors|sector]] C4).
The measurements are performed from the low field side (LFS) in the horizontal midplane (between [[TJ-II:Sectors|sectors]] C4 and C5).
Each frequency corresponds to a different value of the major radius ''R''.  
Each frequency corresponds to a different value of the major radius ''R'' (according to ''B(R)'').  
The system is operated close to the strong [[TJ-II:Electron Cyclotron Resonant Heating|ECR heating source]] (f<sub>ECRH</sub> = 53.2 GHz).  
The system is operated close to the strong [[TJ-II:Electron Cyclotron Resonant Heating|ECR heating source]] (f<sub>ECRH</sub> = 53.2 GHz).  
To protect the radiometer against stray radiation from the gyrotron, the radiometer band is split into two parts.  
To protect the radiometer against stray radiation from the gyrotron, the radiometer band is split into two parts.  
The second harmonic emission above and below 53.2 GHz are measured separately by means of microwave couplers in the signal path.  
The second harmonic emission above and below 53.2 GHz are measured separately by means of microwave couplers in the signal path.
 
== Calibration ==
The system is calibrated absolutely by comparing room temperature with liquid nitrogen temperature.  
The system is calibrated absolutely by comparing room temperature with liquid nitrogen temperature.  
<ref>[http://link.aip.org/link/?RSINAK/72/379/1 E. de la Luna, J. Sánchez, V. Tribaldos, and T. Estrada, ''Multichannel electron cyclotron emission radiometry in TJ-II stellarator'', Rev. Sci. Instrum. '''72''', 379 (2001)]</ref>
<ref name="Luna">[http://link.aip.org/link/?RSINAK/72/379/1 E. de la Luna, J. Sánchez, V. Tribaldos, and T. Estrada, ''Multichannel electron cyclotron emission radiometry in TJ-II stellarator'', Rev. Sci. Instrum. '''72''', 379 (2001)]</ref>
<ref>[http://dx.doi.org/10.1016/S0920-3796(00)00492-0 E. de la Luna et al, ''Electron cyclotron emission measurements on TJ-II stellarator plasmas'', Fusion Engineering and Design '''53''', Issues 1-4 (2001) 147-151]</ref>
<ref>[http://dx.doi.org/10.1016/S0920-3796(00)00492-0 E. de la Luna et al, ''Electron cyclotron emission measurements on TJ-II stellarator plasmas'', Fusion Engineering and Design '''53''', Issues 1-4 (2001) 147-151]</ref>
The optical system and the transmission line of the ECE diagnostic were designed to allow the calibration to be performed outside the vacuum vessel keeping the arrangement of the diagnostic.
To calibrate, the transmission line is opened close to the diagnostic port (C5-bottom). Then the port flange, which holds the optical system and the wave-guide up to that point, is extracted from the torus and assembled with the same alignment outside the vacuum vessel.
A check for the radiometer stability is performed periodically by using a stable noise source at the input of the radiometer. Such a noise source is also used to test the linearity of the system and to calibrate any possible change that may occur in the electronics of the diagnostic.
== Data analysis ==
The emission can be simulated by the [[TRECE]] ray tracing code.
The emission can be simulated by the [[TRECE]] ray tracing code.
<ref>[http://dx.doi.org/10.1088/0029-5515/36/3/I02 V. Tribaldos and B. P. van Milligen, ''Electron cyclotron emission calculations for TJ-II stellarator'', Nucl. Fusion '''36''', 283 (1996)]</ref>
<ref name="Tribal">[http://dx.doi.org/10.1088/0029-5515/36/3/I02 V. Tribaldos and B. P. van Milligen, ''Electron cyclotron emission calculations for TJ-II stellarator'', Nucl. Fusion '''36''', 283 (1996)]</ref>
 
The local radiation temperature is assumed to be a function only of the local electron temperature at the resonant layer; however, if the plasma is not Maxwellian or if the plasma is optically thin, the measured radiation temperature is no longer equal to the electron temperature. 
The effect of polarization rotation can be neglected once the correct polarization for the pure X mode on-axis is chosen. Even at high density (worst condition) the radiation coming from the plasma bulk experiences a rotation below 5&deg;.<ref name="Tribal" />
The spatial resolution is about 1 cm.<ref name="Luna" />
 
The typical sampling rate is 100 kHz.
The typical sampling rate is 100 kHz.
The signals are called 'ECE1' ... 'ECE16' in the [[TJ-II:Shot_database|TJ-II database]].
The raw signals in the [[TJ-II:Shot_database|TJ-II database]] are called 'ECE1' ... 'ECE16', and the processed (calibrated) signals 'TECE1_' ... 'TECE16_' (units: keV).
The measured ECE amplitude is proportional to the electron temperature, provided certain conditions are met.


== References ==
== References ==
<references />
<references />

Revision as of 11:50, 19 August 2010

Diagram showing the position of the ECE antenna-mirror system at TJ-II.

Electron temperature profiles are measured at TJ-II by means of a 16 channel heterodyne radiometer, covering the frequency range 50–60 GHz, corresponding to the second harmonic of electron cyclotron emission (ECE) in X-mode polarization at a magnetic field of 0.95 T on the plasma axis. The measurements are performed from the low field side (LFS) in the horizontal midplane (between sectors C4 and C5). Each frequency corresponds to a different value of the major radius R (according to B(R)). The system is operated close to the strong ECR heating source (fECRH = 53.2 GHz). To protect the radiometer against stray radiation from the gyrotron, the radiometer band is split into two parts. The second harmonic emission above and below 53.2 GHz are measured separately by means of microwave couplers in the signal path.

Calibration

The system is calibrated absolutely by comparing room temperature with liquid nitrogen temperature. [1] [2] The optical system and the transmission line of the ECE diagnostic were designed to allow the calibration to be performed outside the vacuum vessel keeping the arrangement of the diagnostic. To calibrate, the transmission line is opened close to the diagnostic port (C5-bottom). Then the port flange, which holds the optical system and the wave-guide up to that point, is extracted from the torus and assembled with the same alignment outside the vacuum vessel. A check for the radiometer stability is performed periodically by using a stable noise source at the input of the radiometer. Such a noise source is also used to test the linearity of the system and to calibrate any possible change that may occur in the electronics of the diagnostic.

Data analysis

The emission can be simulated by the TRECE ray tracing code. [3]

The local radiation temperature is assumed to be a function only of the local electron temperature at the resonant layer; however, if the plasma is not Maxwellian or if the plasma is optically thin, the measured radiation temperature is no longer equal to the electron temperature. The effect of polarization rotation can be neglected once the correct polarization for the pure X mode on-axis is chosen. Even at high density (worst condition) the radiation coming from the plasma bulk experiences a rotation below 5°.[3] The spatial resolution is about 1 cm.[1]

The typical sampling rate is 100 kHz. The raw signals in the TJ-II database are called 'ECE1' ... 'ECE16', and the processed (calibrated) signals 'TECE1_' ... 'TECE16_' (units: keV).