TJ-II:Coil system: Difference between revisions

From FusionWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 3: Line 3:
The [[TJ-II]] coil system is listed in the table below.
The [[TJ-II]] coil system is listed in the table below.
All coils are directly [[TJ-II:Cooling system|cooled]] by water flowing trough longitudinal holes in the conductors.  
All coils are directly [[TJ-II:Cooling system|cooled]] by water flowing trough longitudinal holes in the conductors.  
All coils have a reinforced structure to avoid mechanical deformations.
All coils have a reinforced structure to avoid mechanical deformations.<ref>M. Medrano, M. Blaumoser, J. Alonso, G. Barrera, M. Pastor, C. Rubio, F. Pedrazo, and O. Heusmann, ''Strength considerations on the magnetic field coils of the Spanish Stellarator TJ-II'', [[doi:10.1109/FUSION.1993.518529| Fusion Engineering, 15th IEEE/NPSS Symposium (1993)]]</ref>


{| class="wikitable"  align="center" border="1"
{| class="wikitable"  align="center" border="1"
Line 10: Line 10:
|Circular (CC) || 1 || ''R'' = 1.5 || 24
|Circular (CC) || 1 || ''R'' = 1.5 || 24
|-
|-
|Helical (HX) || 1 || ''R'' = 1.5 <br> swing = 0.07 || 24
|Helical (HX)<ref>J. Alonso and M. Blaumoser, ''Design and feasibility of the TJ-II hard core'', [[doi:10.1109/FUSION.1991.218810|Fusion Engineering,  14th IEEE/NPSS Symposium (1991)]]</ref> || 1 || ''R'' = 1.5 <br> swing = 0.07 || 24
|-
|-
|Toroidal (TF) || 28 || ''r'' = 0.425 || 8
|Toroidal (TF) || 28 || ''r'' = 0.425 || 8
Line 38: Line 38:
* [[TJ-II:Power supply]]
* [[TJ-II:Power supply]]
* [[TJ-II:Magnetic field]]
* [[TJ-II:Magnetic field]]
== References ==
<references />

Revision as of 14:22, 30 May 2018

The core coil pack consists of three coils: the circular core (CC), the helix 1 (HX1), and the helix 2 (HX2).

The TJ-II coil system is listed in the table below. All coils are directly cooled by water flowing trough longitudinal holes in the conductors. All coils have a reinforced structure to avoid mechanical deformations.[1]

Coil Number Size (m) Turns
Circular (CC) 1 R = 1.5 24
Helical (HX)[2] 1 R = 1.5
swing = 0.07
24
Toroidal (TF) 28 r = 0.425 8
Toroidal (TF) 4 r = 0.475 9
Vertical (VF) 2 R = 2.25 16
Compensation (OH) 2 R = 0.78 20
Compensation (OH) 2 R = 2.29 1
Radial (R) 2 R = 0.74 7
Radial (R) 2 R = 2.24 5

The main helical field is produced by the CC, HX, and TF coils. The vertical field coils (VF) allow positioning the magnetic axis. The ohmic coils (OH) can generate a loop voltage of 0.1 V, intended to cancel spurious toroidal currents. The radial coils (R) produce a trimming radial field of up to 100 G, intended to compensate stray fields.

TJ-II Coils. Red: central. Yellow: helical. Blue: toroidal. Green: vertical. Brown and green: radial.

See also

References

  1. M. Medrano, M. Blaumoser, J. Alonso, G. Barrera, M. Pastor, C. Rubio, F. Pedrazo, and O. Heusmann, Strength considerations on the magnetic field coils of the Spanish Stellarator TJ-II, Fusion Engineering, 15th IEEE/NPSS Symposium (1993)
  2. J. Alonso and M. Blaumoser, Design and feasibility of the TJ-II hard core, Fusion Engineering, 14th IEEE/NPSS Symposium (1991)