OLMAT: Difference between revisions

no edit summary
(Created page with "The OLMAT (Optimization of liquid targets) facility at the Laboratorio Nacional de Fusión is aimed at testing LM (Liquid Metal) prototypes under DEMO-relevant heat loads <ref>Alegre D., Oyarzabal E., Tafalla D., Liniers M., Soleto A. and Tabarés F.L. (2020) ''Design and testing of advanced liquid metal targets for DEMO divertor: the OLMAT project''. J. Fusion Energy 39 411</ref>. File:OLMAT.jpg|400px|thumb|right|CAD design of...")
 
No edit summary
 
Line 1: Line 1:
The OLMAT (Optimization of liquid targets) facility at the [[Laboratorio Nacional de Fusión]] is aimed at testing LM (Liquid Metal) prototypes under DEMO-relevant heat loads <ref>Alegre D., Oyarzabal E., Tafalla D., Liniers M., Soleto A. and Tabarés F.L. (2020) ''Design and testing of advanced liquid metal targets for DEMO divertor: the OLMAT project''. [[doi:10.1007/s10894-020-00254-5|J. Fusion Energy 39 411]]</ref>.  
The OLMAT (Optimization of Liquid Metal Targets) facility at the [[Laboratorio Nacional de Fusión]] is aimed at testing LM (Liquid Metal) prototypes under DEMO-relevant heat loads <ref>Alegre D., Oyarzabal E., Tafalla D., Liniers M., Soleto A. and Tabarés F.L. (2020) ''Design and testing of advanced liquid metal targets for DEMO divertor: the OLMAT project''. [[doi:10.1007/s10894-020-00254-5|J. Fusion Energy 39 411]]</ref>.  


[[File:OLMAT.jpg|400px|thumb|right|CAD design of OLMAT. (a) irradiation chamber; (b) valve to NBI; (c) valve to TJ-II; (d) pre-chamber for sample loading; (e) sample insertion system; (f) upper turbopump with liquid metal condensation bafflers; (g) BaF2 optical window for infrared thermography; (h) diagnostic ports and windows.]]
[[File:OLMAT.jpg|400px|thumb|right|CAD design of OLMAT. (a) irradiation chamber; (b) valve to NBI; (c) valve to TJ-II; (d) pre-chamber for sample loading; (e) sample insertion system; (f) upper turbopump with liquid metal condensation bafflers; (g) BaF2 optical window for infrared thermography; (h) diagnostic ports and windows.]]
Line 7: Line 7:
Moreover, the NBI beam is wide enough to irradiate large samples (<20 cm diameter), allowing redeposition studies of the eroded and evaporated material.  
Moreover, the NBI beam is wide enough to irradiate large samples (<20 cm diameter), allowing redeposition studies of the eroded and evaporated material.  
In a second stage of the project a Q-CW, high-power fibre laser is used to simulate ELM-like powers in a small area, or the strike point power deposition profile.
In a second stage of the project a Q-CW, high-power fibre laser is used to simulate ELM-like powers in a small area, or the strike point power deposition profile.
[[File:OLMAT1.png|500px|thumb|center|The OLMAT facility and TJ-II]]


== References ==
== References ==
<references />
<references />