To minimize the accelerator activation, the commissioning will be performed mainly with H2+ pulsed beams with progressively increasing duty factor and current up to the nominal 125mA current. Therefore the beam dump must be able to stop deuteron and H2+ continuous and pulsed beams with energies 5MeV (RFQ commissioning) and 9MeV. The maximum beam power is 1.12MW corresponding to a beam current of 125mA. A maximum operation time at full current of D+ of around 1 year and an operation time with 5Hz pulsed beam with 0.1% duty cycle of 2 months have been assumed.  
To minimize the accelerator activation, the commissioning will be performed mainly with H<sup>2+</sup> pulsed beams with progressively increasing duty factor and current up to the nominal 125 mA current. Therefore the beam dump must be able to stop deuteron and H<sup>2+</sup> continuous and pulsed beams with energies 5 MeV (RFQ commissioning) and 9 MeV. The maximum beam power is 1.12 MW corresponding to a beam current of 125 mA. A maximum operation time at full current of D+ of around 1 year and an operation time with 5 Hz pulsed beam with 0.1% duty cycle of 2 months have been assumed.
 