Diagnostics: Difference between revisions

From FusionWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 2: Line 2:


Diagnostics are the eyes and ears of fusion reactors. They return vital parameters such as the temperature, the density, the impurity content, the magnetic field et cetera.  
Diagnostics are the eyes and ears of fusion reactors. They return vital parameters such as the temperature, the density, the impurity content, the magnetic field et cetera.  
Below you find a list of different diagnostics, together with their main measurement parameters.
A distinction can be made between ''active'' and ''passive'' diagnostics (the former requiring the injection of light beams, particles, or probes, while the latter is based on the observation of radiation and particles emitted spontaneously by the plasma).
 
Below follows a list of different diagnostics, together with their main measurement parameters.




Line 16: Line 16:
|-
|-
|Electron Cyclotron Emission || ECE, ECEi || Electron temperature <math>T_e</math>, electron temperature fluctuations (turbulence) <math>\tilde{T}_e</math>
|Electron Cyclotron Emission || ECE, ECEi || Electron temperature <math>T_e</math>, electron temperature fluctuations (turbulence) <math>\tilde{T}_e</math>
|-
|Soft X-Ray Emission || SXR || A combination of electron temperature <math>T_e</math>, electron density <math>n_e</math>, and effective charge <math>Z_{eff}</math>
|-
|-
|Mirnov coils, pickup coils || - || magnetic field components and fluctuations (outside plasma)
|Mirnov coils, pickup coils || - || magnetic field components and fluctuations (outside plasma)

Revision as of 23:24, 31 May 2012

A prominence on the sun, an arc of plasma rising into the corona. Image credit: Solar Dynamics Observatory (April, 2010)

Diagnostics are the eyes and ears of fusion reactors. They return vital parameters such as the temperature, the density, the impurity content, the magnetic field et cetera. A distinction can be made between active and passive diagnostics (the former requiring the injection of light beams, particles, or probes, while the latter is based on the observation of radiation and particles emitted spontaneously by the plasma). Below follows a list of different diagnostics, together with their main measurement parameters.


Name Abbreviation Measurement parameters
Thomson Scattering TS Electron temperature , electron density
Charge Exchange Recombination Spectroscopy CXRS, CXS, CHERS, CER Ion temperature , toroidal and poloidal plasma rotation velocity , , impurity density
Motional Stark Effect MSE Magnetic pitch angle
Electron Cyclotron Emission ECE, ECEi Electron temperature , electron temperature fluctuations (turbulence)
Soft X-Ray Emission SXR A combination of electron temperature , electron density , and effective charge
Mirnov coils, pickup coils - magnetic field components and fluctuations (outside plasma)
Heavy Ion Beam Probe HIBP Electron density , plasma potential
Interferometry - Electron density (line integral)
Polarimetry - Magnetic field pitch (line integral)
Reflectometry - Electron density (edge profile, fluctuations)


A special bi-annual conference on fusion diagnostics is held in the U.S.: The Topical Conference on High Temperature Plasma Diagnostics (HTPD)

References

  • I.H. Hutchinson, Principles of Plasma Diagnostics, Cambridge University Press; 2nd edition (2002) ISBN 978-0521803892