TJ-II:Magnetics: Difference between revisions

no edit summary
No edit summary
No edit summary
Line 5: Line 5:
TJ-II is fitted with an ample set of Mirnov coils:
TJ-II is fitted with an ample set of Mirnov coils:
<ref>[http://www.new.ans.org/pubs/journals/fst/a_1283 R. Jiménez-Gómez et al., Fusion Science and Technology '''51''', 20 (2007)]</ref>
<ref>[http://www.new.ans.org/pubs/journals/fst/a_1283 R. Jiménez-Gómez et al., Fusion Science and Technology '''51''', 20 (2007)]</ref>
* Two straight arrays above the plasma column, each with 12 coils, mounted in a 0.5 mm thick stainless steel tube attached to a port flange. The 12 coils are distributed in 4 groups of 3 coils each, separated by a distance of 30 mm. The three coils in each group measure the three cylindrical components (''R'', ''Z'', and ''&phi;'') of the magnetic field. They are located in [[TJ-II:Sectors|sectors]] B5 and C4, at ''&phi;'' = 232 and 308 degrees.
* Two straight arrays above the plasma column, each with 12 coils, mounted in a 0.5 mm thick stainless steel tube attached to a port flange. The 12 coils are distributed in 4 groups of 3 coils each, separated by a distance of 30 mm. The three coils in each group measure the three cylindrical components (''R'', ''Z'', and ''&phi;'') of the magnetic field. They are located in [[TJ-II:Sectors|sectors]] B5 and C4, at ''&phi;'' = 232&deg; and 308&deg;.
* One poloidal array with 15 coils measuring the poloidal field component. This array is located between [[TJ-II:Sectors|sectors]] D4 and D5, at ''&phi;'' = 45 degrees.
* One poloidal array with 15 coils measuring the poloidal field component. This array is located between [[TJ-II:Sectors|sectors]] D4 and D5, at ''&phi;'' = 45&deg;.


== Rogowski coils ==
== Rogowski coils ==


Two Rogowski coils have been installed in [[TJ-II:Sectors|sectors]] A5 (148.7&deg;) and B4 (211.3&deg;) ''(Note: the angles are inconsistent)''. Since the coils have to surround the plasma column completely, they are located under the protecting tiles of the groove that runs toroidally all along the [[TJ-II:Vacuum system|vacuum vessel]]. For this purpose, 2 mm deep channels were machined on the vacuum side of the groove, at the above mentioned poloidal cross sections, in order to allow enough space for the coils.
Two Rogowski coils have been installed in [[TJ-II:Sectors|sectors]] A5 (148.7&deg;) and B4 (211.3&deg;). Since the coils have to surround the plasma column completely, they are located under the protecting tiles of the groove that runs toroidally all along the [[TJ-II:Vacuum system|vacuum vessel]]. For this purpose, 2 mm deep channels were machined on the vacuum side of the groove, at the above mentioned poloidal cross sections, in order to allow enough space for the coils.


The signals 'Ip_a5_' and 'Ip_b4_' in the [[TJ-II:Shot database|TJ-II database]] provide the corresponding measurements of the net plasma current.