Connection length

Revision as of 11:36, 26 January 2023 by Admin (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

The connection length is understood to be the distance between two points, measured along a magnetic field line passing through these points.

In the fusion context, a distinction is made between closed field lines (inside the Last Closed Flux Surface) and open field lines (outside).

Closed field lines

In a toroidally confined plasma, inside the Last Closed Flux Surface, the connection length is commonly defined as the length, measured along the magnetic field, to complete a poloidal turn.

In a circular tokamak, the poloidal circumference is 2πr. The connection length is  , where   is the pitch angle of the field line, namely  . Assuming  , one has  , so that [1]

 

where q is the safety factor, approximated by  .

Open field lines

Outside Last Closed Flux Surface, the connection length associated with a given point is defined as the shortest distance from that point to any material surface measured along the field line through that point.

References

  1. K. Miyamoto, Plasma Physics and Controlled Nuclear Fusion, Springer-Verlag (2005) ISBN 3540242171