TJ-IU
Jump to navigation
Jump to search
In the torsatron TJ-IU, a single coil generates the helicoidal magnetic field (l=1). The number of turns of the coil around the vacuum chamber is m=6. The vertical field is generated by a set of vertical field coils.
Parameter | Value | Unit |
---|---|---|
Major radius, R0: | 0.60 | m |
Mean plasma radius, a: | 0.10 | m |
Minor coil radius, Rc: | 0.24 | m |
Number of periods, m: | 6 | |
Rotational transform at the axis, ι0: | 0.30 | |
Magnetic shear: | almost zero | |
Magnetic well depth: | 6.9 | % |
Magnetic ripple at the axis: | 7.6 | % |
Helical axis elongation: | 0.025 | m |
Toroidal field, BT, at φ=30 degrees: | 0.5 | T |
2nd harmonic Electron Cyclotron Heating, 28 - 37.5 GHz: | 200 | kW |
The device was entirely built in Spain and taken into operation in 1994. In 1999, the device was sent to the University of Kiel, Germany, under a permanent loan agreement, and renamed TJ-K. Currently, TJ-K is located at the University of Stuttgart in Germany.
External links
References
- M.A. Pedrosa, M.A. Ochando, J.A. Jiménez, R. Balbín, J. Qin, and C. Hidalgo, Magnetic configuration effects on the TJ-IU torsatron plasma edge turbulence, Plasma Phys. Control. Fusion 38 (1996) 365
- E. Ascasibar, J. Qin, A.L. Fraguas, I. Pastor and J. Herranz, Measurement of magnetic surfaces on the TJ-I U torsatron, Nucl. Fusion 37, 6 (1997) 851