Plasma performance is often expressed in terms of beta (β), defined as: [1]
i.e., the ratio of the plasma pressure to the magnetic pressure. Here, <p> is the mean plasma pressure, and B the mean total field strength. It is customary to introduce also the poloidal β (βp) and the toroidal β (βt), in which B is replaced by the poloidal and toroidal magnetic field component, respectively. One has:
Normalized beta
The normalized beta (or Troyon factor) is an operational parameter indicating how close the plasma is to reaching the Greenwald limit. Its definition is (for tokamaks): [2]
where B is in T, a in m, and Ip in MA.