TJ-II:Coil system: Difference between revisions

From FusionWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 3: Line 3:
The [[TJ-II]] coil system is listed in the table below.
The [[TJ-II]] coil system is listed in the table below.
All coils are directly [[TJ-II:Cooling system|cooled]] by water flowing trough longitudinal holes in the conductors.  
All coils are directly [[TJ-II:Cooling system|cooled]] by water flowing trough longitudinal holes in the conductors.  
All coils have a reinforced structure to avoid mechanical deformations.
All coils have a reinforced structure to avoid mechanical deformations.<ref>M. Medrano, M. Blaumoser, J. Alonso, G. Barrera, M. Pastor, C. Rubio, F. Pedrazo, and O. Heusmann, ''Strength considerations on the magnetic field coils of the Spanish Stellarator TJ-II'', [[doi:10.1109/FUSION.1993.518529| Fusion Engineering, 15th IEEE/NPSS Symposium (1993)]]</ref>


{| class="wikitable"  align="center" border="1"
{| class="wikitable"  align="center" border="1"
Line 10: Line 10:
|Circular (CC) || 1 || ''R'' = 1.5 || 24
|Circular (CC) || 1 || ''R'' = 1.5 || 24
|-
|-
|Helical (HX) || 1 || ''R'' = 1.5 <br> swing = 0.07 || 24
|Helical (HX)<ref>J. Alonso and M. Blaumoser, ''Design and feasibility of the TJ-II hard core'', [[doi:10.1109/FUSION.1991.218810|Fusion Engineering,  14th IEEE/NPSS Symposium (1991)]]</ref> || 1 || ''R'' = 1.5 <br> swing = 0.07 || 24
|-
|-
|Toroidal (TF) || 28 || ''r'' = 0.425 || 8
|Toroidal (TF) || 28 || ''r'' = 0.425 || 8
Line 38: Line 38:
* [[TJ-II:Power supply]]
* [[TJ-II:Power supply]]
* [[TJ-II:Magnetic field]]
* [[TJ-II:Magnetic field]]
== References ==
<references />

Revision as of 14:22, 30 May 2018

The core coil pack consists of three coils: the circular core (CC), the helix 1 (HX1), and the helix 2 (HX2).

The TJ-II coil system is listed in the table below. All coils are directly cooled by water flowing trough longitudinal holes in the conductors. All coils have a reinforced structure to avoid mechanical deformations.[1]

Coil Number Size (m) Turns
Circular (CC) 1 R = 1.5 24
Helical (HX)[2] 1 R = 1.5
swing = 0.07
24
Toroidal (TF) 28 r = 0.425 8
Toroidal (TF) 4 r = 0.475 9
Vertical (VF) 2 R = 2.25 16
Compensation (OH) 2 R = 0.78 20
Compensation (OH) 2 R = 2.29 1
Radial (R) 2 R = 0.74 7
Radial (R) 2 R = 2.24 5

The main helical field is produced by the CC, HX, and TF coils. The vertical field coils (VF) allow positioning the magnetic axis. The ohmic coils (OH) can generate a loop voltage of 0.1 V, intended to cancel spurious toroidal currents. The radial coils (R) produce a trimming radial field of up to 100 G, intended to compensate stray fields.

TJ-II Coils. Red: central. Yellow: helical. Blue: toroidal. Green: vertical. Brown and green: radial.

See also

References

  1. ↑ M. Medrano, M. Blaumoser, J. Alonso, G. Barrera, M. Pastor, C. Rubio, F. Pedrazo, and O. Heusmann, Strength considerations on the magnetic field coils of the Spanish Stellarator TJ-II, Fusion Engineering, 15th IEEE/NPSS Symposium (1993)
  2. ↑ J. Alonso and M. Blaumoser, Design and feasibility of the TJ-II hard core, Fusion Engineering, 14th IEEE/NPSS Symposium (1991)