TJ-II:Magnetics: Difference between revisions

From FusionWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 10: Line 10:
== Rogowski coils ==
== Rogowski coils ==


== Diamagnetic loop ==
== Diamagnetic loops ==
 
Two internal diamagnetic loops are installed at φ = 135º and 225º.
They consist of a main loop which encircles the plasma column
and runs under the protecting tiles in the groove region and a compensating loop which
measures only the vacuum magnetic flux.


== References ==
== References ==
<references />
<references />

Revision as of 17:31, 6 August 2009

Mirnov coils

The poloidal array of Mirnov coils at TJ-II

TJ-II is fitted with an ample set of Mirnov coils: [1]

  • Two straight arrays above the plasma column, each with 12 coils measuring the three cylindrical components (R, Z, and φ) of the magnetic field. They are located in sectors B5 and C4, at φ = 142 and 218 degrees.
  • One poloidal array with 15 coils measuring the poloidal field component. This array is located between sectors D4 and D5, at φ = 315 degrees.

Rogowski coils

Diamagnetic loops

Two internal diamagnetic loops are installed at φ = 135º and 225º. They consist of a main loop which encircles the plasma column and runs under the protecting tiles in the groove region and a compensating loop which measures only the vacuum magnetic flux.

References