TJ-II:Lithium Beam: Difference between revisions

From FusionWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 1: Line 1:
[[File:Li_beam.jpg|300px|thumb|right|Lithium beam diagnostic setup.]]
[[File:Li_beam.jpg|300px|thumb|right|Lithium beam diagnostic setup. For a photo, see [[TJ-II:Helium Beam|Helium Beam]].]]
[[TJ-II]] possesses a Lithium beam diagnostic.
[[TJ-II]] possesses a Lithium beam diagnostic.
A thermal Li beam source, located at ∼ 80 cm from the observation region, has been used for the reconstruction of the SOL and edge parameters of the plasmas.  
A thermal Li beam source, located at ∼ 80 cm from the observation region, has been used for the reconstruction of the SOL and edge parameters of the plasmas.  

Revision as of 18:13, 30 August 2010

Lithium beam diagnostic setup. For a photo, see Helium Beam.

TJ-II possesses a Lithium beam diagnostic. A thermal Li beam source, located at ∼ 80 cm from the observation region, has been used for the reconstruction of the SOL and edge parameters of the plasmas. A 16 channel photomultiplier array allowed the continuous recording of the radial profile of Li* emission. Detection of the Li* emission up to 8 cm inside the last closed flux surface (corresponding to r/a < 0.7) was possible. [1] [2] [3]

The system is located in sector C7. The signals are stored in the TJ-II database with the names 'LITIO1',...,'LITIO16'.

References