TJ-II:Interferometry: Difference between revisions
Line 19: | Line 19: | ||
<ref>[http://link.aip.org/link/?APCPCS/993/187/1 M. Sánchez et al, ''Admissible Crosstalk Limits in a Two Colour Interferometers for Plasma Density Diagnostics. A Reduction Algorithm'', PLASMA 2007, AIP Conf. Proc. '''993''' (2008) 187-190]</ref> | <ref>[http://link.aip.org/link/?APCPCS/993/187/1 M. Sánchez et al, ''Admissible Crosstalk Limits in a Two Colour Interferometers for Plasma Density Diagnostics. A Reduction Algorithm'', PLASMA 2007, AIP Conf. Proc. '''993''' (2008) 187-190]</ref> | ||
<ref>[http://link.aip.org/link/?RSINAK/79/10E713/1 P. Acedo et al, ''Calibration of a high spatial resolution laser two-color heterodyne interferometer for density profile measurements in the TJ-II stellarator'', Rev. Sci. Instrum. '''79''' (2008) 10E713]</ref> | <ref>[http://link.aip.org/link/?RSINAK/79/10E713/1 P. Acedo et al, ''Calibration of a high spatial resolution laser two-color heterodyne interferometer for density profile measurements in the TJ-II stellarator'', Rev. Sci. Instrum. '''79''' (2008) 10E713]</ref> | ||
<ref>[http://dx.doi.org/10.1016/j.fusengdes.2010.03.036 L. Esteban, M. Sánchez, J.A. López, O. Nieto-Taladriz and J. Sánchez, ''Continuous plasma density measurement in TJ-II infrared interferometer—Advanced signal processing based on FPGAs'', Fus- Eng. Designs (2010) in press]</ref> | |||
The system is located in [[TJ-II:Sectors|sector]] B1. | The system is located in [[TJ-II:Sectors|sector]] B1. | ||
==References== | ==References== | ||
<references /> | <references /> |
Revision as of 09:52, 26 April 2010
TJ-II has two interferometry systems for the measurement of the line-integrated density.
The Microwave interferometer
The diagnostic is located in sector B8. The probing beam has an inclination of 18.7º with respect to the vertical and a frequency of 140 GHz, corresponding to a wavelength of λ = 2.14 mm. The diagnostic provides a time trace of the line-integrated electron density (65536 points, sampling rate 100 kHz). The time trace is called 'Densidad2_' in the TJ-II database. The signal is less reliable for high densities (above 2-3 1019 m-3). This time trace is fundamental for machine operation.
Two-colour interferometer
The double wavelength heterodyne interferometer (CO2: 10.6 μm, NdYAG: 1.064 μm) provides values of the plasma line integral density in scenarios with average densities ranging from a few times 1018 m–3 to more than 5×1019 m–3. The results have been compared with those from the 2 mm (microwave) interferometer, obtaining an excellent agreement. Working with a final bandwidth of 4 kHz, a one pass line integral error level about ±2×1017 m–2 has been achieved. [1] [2] [3] [4] [5] [6] The system is located in sector B1.
References
- ↑ H. Lamela et al, Laser interferometric experiments for the TJ-II stellarator electron-density measurements, Rev. Sci. Instrum. 72 (2001) 96
- ↑ M. Sánchez at al, High resolution CO2 interferometry on the TJ-II stellarator by using an ADC-based phase meter, Rev. Sci. Instrum. 75 (2004) 3414
- ↑ P. Acedo et al, CO2 (λm = 10.6 μm) He–Ne (λc = 633 nm) two-color laser interferometry for low and medium electron density measurements in the TJ-II Stellarator, Rev. Sci. Instrum. 75, 11 (2004) 4671
- ↑ M. Sánchez et al, Admissible Crosstalk Limits in a Two Colour Interferometers for Plasma Density Diagnostics. A Reduction Algorithm, PLASMA 2007, AIP Conf. Proc. 993 (2008) 187-190
- ↑ P. Acedo et al, Calibration of a high spatial resolution laser two-color heterodyne interferometer for density profile measurements in the TJ-II stellarator, Rev. Sci. Instrum. 79 (2008) 10E713
- ↑ L. Esteban, M. Sánchez, J.A. López, O. Nieto-Taladriz and J. Sánchez, Continuous plasma density measurement in TJ-II infrared interferometer—Advanced signal processing based on FPGAs, Fus- Eng. Designs (2010) in press