TJ-II:Compact Neutral Particle Analyzer: Difference between revisions

From FusionWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 2: Line 2:
A Compact Neutral Particle Analyzer (CNPA), developed by the A.F. Ioffe Physical-Technical Institute, has been installed on [[TJ-II]].  
A Compact Neutral Particle Analyzer (CNPA), developed by the A.F. Ioffe Physical-Technical Institute, has been installed on [[TJ-II]].  
<ref>[http://epsppd.epfl.ch/StPetersburg/PDF/P4_071.PDF F.V. Chernyshev et al, ''Compact Neutral Particle Analyzer for plasma diagnostics'', 30<sup>th</sup> EPS Conference on Contr. Fusion and Plasma Phys. Vol. 27A (2003) P-4.71]</ref>
<ref>[http://epsppd.epfl.ch/StPetersburg/PDF/P4_071.PDF F.V. Chernyshev et al, ''Compact Neutral Particle Analyzer for plasma diagnostics'', 30<sup>th</sup> EPS Conference on Contr. Fusion and Plasma Phys. Vol. 27A (2003) P-4.71]</ref>
<ref>F.V. Chernyshev et al, Instruments and Experimental Techniques '''47''', 2 (2004) 214-220</ref>
<ref>[http://dx.doi.org/10.1023/B:INET.0000025204.01783.1a F.V. Chernyshev et al, Instruments and Experimental Techniques '''47''', 2 (2004) 214-220]</ref>
It detects H<sup>0</sup> atoms in the energy range from 1 to 44 keV, and has 16 detection channels at fixed energy.  
It detects H<sup>0</sup> atoms in the energy range from 1 to 44 keV, and has 16 detection channels at fixed energy.  
It is installed in [[TJ-II:Sectors|sector]] B1.
It is installed in [[TJ-II:Sectors|sector]] B1.
This diagnostic is devoted to study the high-energy tails during Neutral Beam Injection heating.
This diagnostic is devoted to studying the high-energy tails during Neutral Beam Injection heating.
<ref>[http://epsppd.epfl.ch/Tarragona/pdf/D5_001.pdf R. Balbín et al, ''First Measurements of High-Energy Charge-Exchange Neutrals Using Compact Neutral Particle Analyser in TJ-II Stellarator'', 32<sup>nd</sup> EPS Conference on Plasma Phys. (Tarragona, 2005) ECA Vol.29C (2005) D-5.001]</ref>
<ref>[http://epsppd.epfl.ch/Tarragona/pdf/D5_001.pdf R. Balbín et al, ''First Measurements of High-Energy Charge-Exchange Neutrals Using Compact Neutral Particle Analyser in TJ-II Stellarator'', 32<sup>nd</sup> EPS Conference on Plasma Phys. (Tarragona, 2005) ECA Vol.29C (2005) D-5.001]</ref>


== References ==
== References ==
<references />
<references />

Revision as of 16:51, 18 October 2009

The Compact Neutral Particle Analyzer / Charge Exchange Recombination Spectroscopy diagnostic at TJ-II

A Compact Neutral Particle Analyzer (CNPA), developed by the A.F. Ioffe Physical-Technical Institute, has been installed on TJ-II. [1] [2] It detects H0 atoms in the energy range from 1 to 44 keV, and has 16 detection channels at fixed energy. It is installed in sector B1. This diagnostic is devoted to studying the high-energy tails during Neutral Beam Injection heating. [3]

References