TJ-II:Charge exchange spectroscopy: Difference between revisions
No edit summary |
No edit summary |
||
Line 5: | Line 5: | ||
The diagnostic can be controlled remotely. | The diagnostic can be controlled remotely. | ||
<ref>[http://dx.doi.org/10.1016/S0920-3796(02)00051-0 A. López et al, ''Software and hardware developments for remote participation in TJ-II operation. Proof of concept using the NPA diagnostic'', Fusion Engineering and Design '''60''', Issue 3 (2002) 487-492]</ref> | <ref>[http://dx.doi.org/10.1016/S0920-3796(02)00051-0 A. López et al, ''Software and hardware developments for remote participation in TJ-II operation. Proof of concept using the NPA diagnostic'', Fusion Engineering and Design '''60''', Issue 3 (2002) 487-492]</ref> | ||
<ref>[http://link.aip.org/link/?RSINAK/74/1795/1 F. Castejón et al, ''Results of the remote participation on TJ-II neutral particle analyzer'', Rev. Sci. Instrum. '''74''' (2003) 1795]</ref> | |||
== References == | == References == | ||
<references /> | <references /> |
Revision as of 09:30, 15 October 2009
At TJ-II, the ion temperature profile has been measured using a charge exchange neutral particle analyser (CX-NPA). The CX-NPA gives the energy spectrum of plasma ions at one point per shot, and the ion temperature can be calculated from this spectrum assuming a Maxwellian energy distribution function. The analyser can perform a poloidal scan covering a low magnetic field section at constant toroidal angle near φ = 85º. Moreover, the particle flux is collimated in order that the tested plasma volume is small (the diameter is about 10 mm on magnetic axis). Due to the geometry of the device, the collected particle beam is very narrow and positioned almost perpendicular to magnetic field, therefore, the pitch of the collected particles is very small, tan-1(v ||/vper) ≤ 3.1·10–2 rad, which means that only the perpendicular velocity of trapped particles is measured. A radial profile is obtained using a series of reproducible discharges. [1] [2]
The diagnostic can be controlled remotely. [3] [4]
References
- ↑ R. Balbín et al, Ion confinement studies on the TJ-II stellarator , 14th Stellarator Workshop, Greifswald (2003)
- ↑ J.M. Fontdecaba et al, Ion heat transport analysis in TJ-II plasmas, 14th Stellarator Workshop, Greifswald (2003)
- ↑ A. López et al, Software and hardware developments for remote participation in TJ-II operation. Proof of concept using the NPA diagnostic, Fusion Engineering and Design 60, Issue 3 (2002) 487-492
- ↑ F. Castejón et al, Results of the remote participation on TJ-II neutral particle analyzer, Rev. Sci. Instrum. 74 (2003) 1795