TJ-II:Reflectometry: Difference between revisions

From FusionWiki
Jump to navigation Jump to search
No edit summary
mNo edit summary
Line 17: Line 17:


[[File:DRscheme.jpg|200px|thumb|right|Schematic drawing of the Doppler Reflectometer System of TJ-II.]]
[[File:DRscheme.jpg|200px|thumb|right|Schematic drawing of the Doppler Reflectometer System of TJ-II.]]
Since February 2009, the frequency hopping system is in operation in oblique incidence (''Doppler'' reflectometry, [[TJ-II:Sectors|sector]] C6) <ref>[http://link.aip.org/link/?RSINAK/80/073502/1 T. Happel, T. Estrada, E. Blanco, V. Tribaldos, A. Cappa, and A. Bustos, Rev. Sci. Instrum. '''80''' (2009) 073502]</ref>, measuring plasma density fluctuation velocities and their wave number spectra. The system is able to measure in a radial range of about &rho; = 0.6 - 0.9 (&rho;=r/a is the effective radius) and the perpendicular wavenumber can be selected between 3 and 15 cm<sup>-1</sup>.
Since February 2009, the frequency hopping system is in operation in oblique incidence (''Doppler'' reflectometry, [[TJ-II:Sectors|sector]] C6) <ref>[http://link.aip.org/link/?RSINAK/80/073502/1 T. Happel, T. Estrada, E. Blanco, V. Tribaldos, A. Cappa, and A. Bustos, Rev. Sci. Instrum. '''80''' (2009) 073502]</ref>, measuring plasma density fluctuation velocities and their wave number spectra. The system is able to measure in a radial range of about &rho; = 0.6 - 0.9 (&rho; = r/a is the effective plasma radius) and the perpendicular wavenumber can be selected between 3 and 15 cm<sup>-1</sup>.


==References==
==References==
<references />
<references />

Revision as of 15:52, 22 July 2009

Profile Reflectometer

TJ-II has an AM reflectometer [1] for measuring electron density profiles with a temporal resolution of 2 ms (located between sectors A4 and A5).

Fluctuation Reflectometer

A fast frequency hopping reflectometer [2] working in the Q-band (33 - 50 GHz) was used from 2004 - 2008 in perpendicular incidence (conventional reflectometry) [3] .

Doppler Reflectometer

Schematic drawing of the Doppler Reflectometer System of TJ-II.

Since February 2009, the frequency hopping system is in operation in oblique incidence (Doppler reflectometry, sector C6) [4], measuring plasma density fluctuation velocities and their wave number spectra. The system is able to measure in a radial range of about ρ = 0.6 - 0.9 (ρ = r/a is the effective plasma radius) and the perpendicular wavenumber can be selected between 3 and 15 cm-1.

References