A Compact Neutral Particle Analyzer (CNPA), developed by the A.F. Ioffe Physical-Technical Institute, has been installed on [[TJ-II]]. | A Compact Neutral Particle Analyzer (CNPA), developed by the A.F. Ioffe Physical-Technical Institute, has been installed on [[TJ-II]]. | ||
<ref>[http://epsppd.epfl.ch/StPetersburg/PDF/P4_071.PDF F.V. Chernyshev et al, ''Compact Neutral Particle Analyzer for plasma diagnostics'', 30<sup>th</sup> EPS Conference on Contr. Fusion and Plasma Phys. Vol. 27A (2003) P-4.71]</ref> | <ref>[http://epsppd.epfl.ch/StPetersburg/PDF/P4_071.PDF F.V. Chernyshev et al, ''Compact Neutral Particle Analyzer for plasma diagnostics'', 30<sup>th</sup> EPS Conference on Contr. Fusion and Plasma Phys. Vol. 27A (2003) P-4.71]</ref> | ||
<ref>[http://dx.doi.org/10.1023/B:INET.0000025204.01783.1a F.V. Chernyshev et al, Instruments and Experimental Techniques '''47''', 2 (2004) 214-220]</ref> | <ref>[http://dx.doi.org/10.1023/B:INET.0000025204.01783.1a F.V. Chernyshev et al, ''A Compact Neutral-Particle Analyzer for Plasma Diagnostics'', Instruments and Experimental Techniques '''47''', 2 (2004) 214-220]</ref> | ||
It detects H<sup>0</sup> atoms in the energy range from 1 to 44 keV, and has 16 detection channels at fixed energy. | It detects H<sup>0</sup> atoms in the energy range from 1 to 44 keV, and has 16 detection channels at fixed energy. | ||
It is installed in [[TJ-II:Sectors|sector]] B1. | It is installed in [[TJ-II:Sectors|sector]] B1. |
Revision as of 16:53, 18 October 2009
A Compact Neutral Particle Analyzer (CNPA), developed by the A.F. Ioffe Physical-Technical Institute, has been installed on TJ-II. [1] [2] It detects H0 atoms in the energy range from 1 to 44 keV, and has 16 detection channels at fixed energy. It is installed in sector B1. This diagnostic is devoted to studying the high-energy tails during Neutral Beam Injection heating. [3]
References
- ↑ F.V. Chernyshev et al, Compact Neutral Particle Analyzer for plasma diagnostics, 30th EPS Conference on Contr. Fusion and Plasma Phys. Vol. 27A (2003) P-4.71
- ↑ F.V. Chernyshev et al, A Compact Neutral-Particle Analyzer for Plasma Diagnostics, Instruments and Experimental Techniques 47, 2 (2004) 214-220
- ↑ R. Balbín et al, First Measurements of High-Energy Charge-Exchange Neutrals Using Compact Neutral Particle Analyser in TJ-II Stellarator, 32nd EPS Conference on Plasma Phys. (Tarragona, 2005) ECA Vol.29C (2005) D-5.001