TJ-II:Shot database: Difference between revisions

From FusionWiki
Jump to navigation Jump to search
No edit summary
 
(15 intermediate revisions by 7 users not shown)
Line 2: Line 2:


Raw data are stored in the database as soon as the data acquisition process of a [[TJ-II]] discharge is finished.
Raw data are stored in the database as soon as the data acquisition process of a [[TJ-II]] discharge is finished.
Relevant accompanying factors (e.g., calibration constants) can be stored with the data. After storage, the raw data cannot be modified.
Relevant accompanying factors (e.g., calibration constants, offsets) can be stored with the data. After storage, the raw data cannot be modified.


Processed data can be incorporated at any time after the discharge, and can be overwritten if needed. The signal names of processed data terminate in an underscore.
Processed data can be incorporated at any time after the discharge, and can be overwritten if needed. The signal names of processed data terminate in an underscore.


The documents referred to in the following are available on-line  
== Documentation ==
 
The documents referred to below are available on-line  
[http://www-fusion.ciemat.es/cgi-bin/dir/dirnew.cgi?manuals/Databases_TJII/ here] (internal laboratory access only).
[http://www-fusion.ciemat.es/cgi-bin/dir/dirnew.cgi?manuals/Databases_TJII/ here] (internal laboratory access only).


== Documentation ==
* General information about the TJ-II Shot Database<ref>J. Vega, C. Crémy, E. Sánchez, A. Portas, J. A. Fábregas, R. Herrera, ''Data management in the TJ-II multi-layer database'', [[doi:10.1016/S0920-3796(00)00133-2|Fus. Eng. and Design '''48''' (2000) 69-79]]</ref>
 
* [http://fudaqs2.ciemat.es/TJ2WEB/AyudaDatos/index.htm The software library for accessing the raw data]<ref>J. Vega, E. Sánchez, C. Crémy, A. Portas, C. M. Dulya, J. Nilsson, ''TJ-II data retrieving by means of a client/server model'', [[doi:10.1063/1.1149283|Rev. Sci. Instr. '''70''' (1) (1999) 498]]</ref>
* General information about the TJ-II Shot Database<ref>[http://dx.doi.org/10.1016/S0920-3796(00)00133-2 J. Vega, C. Crémy, E. Sánchez, A. Portas, J. A. Fábregas, R. Herrera, ''Data management in the TJ-II multi-layer database'', Fus. Eng. and Design '''48''' (2000) 69-79]</ref>
* The Remote Procedure Call (RPC) library for accessing data<ref>E. Sánchez, J. Vega, C. Crémy and A. Portas, ''Accessing TJ-II data with remote procedure call'', [[doi:10.1063/1.1316757|Rev. Sci. Instr. '''72''' (1) (2001) 525-529]]</ref>
* [http://fudaqs2.ciemat.es/TJ2WEB/AyudaDatos/index.htm The software library for accessing the raw data]<ref>[http://link.aip.org/link/?RSINAK/70/498/1 J. Vega, E. Sánchez, C. Crémy, A. Portas, C. M. Dulya, J. Nilsson, ''TJ-II data retrieving by means of a client/server model'', Rev. Sci. Instr. '''70''' (1) (1999) 498]</ref>
* Data access interface routines for MatLab: [http://intranet-fusion.ciemat.es/ Intranet, National Fusion Laboratory (CIEMAT)] / Document Server / Manuals and Software / Matlab acceso datos TJ-II
* The Remote Procedure Call (RPC) library for accessing data<ref>[http://link.aip.org/link/?RSINAK/72/525/1 E. Sánchez, J. Vega, C. Crémy and A. Portas, ''Accessing TJ-II data with remote procedure call'', Rev. Sci. Instr. '''72''' (1) (2001) 525-529]</ref>
* [https://www.ciemat.es/portal.do?TR=A&IDR=1&identificador=1093 TJ-II Web Services], a web interface for access to the TJ-II database


== See also ==
== See also ==


* [[TJ-II:Relational database|TJ-II Relational database]]
* [[TJ-II:Relational database|TJ-II Relational database]]
* [[MDSplus]]


== References ==
== References ==
<references />
<references />

Latest revision as of 08:44, 17 July 2024

Raw data and data with minimal processing are stored in the TJ-II Shot Database, which allows storing both time traces and spatial profiles.

Raw data are stored in the database as soon as the data acquisition process of a TJ-II discharge is finished. Relevant accompanying factors (e.g., calibration constants, offsets) can be stored with the data. After storage, the raw data cannot be modified.

Processed data can be incorporated at any time after the discharge, and can be overwritten if needed. The signal names of processed data terminate in an underscore.

Documentation

The documents referred to below are available on-line here (internal laboratory access only).

See also

References

  1. J. Vega, C. Crémy, E. Sánchez, A. Portas, J. A. Fábregas, R. Herrera, Data management in the TJ-II multi-layer database, Fus. Eng. and Design 48 (2000) 69-79
  2. J. Vega, E. Sánchez, C. Crémy, A. Portas, C. M. Dulya, J. Nilsson, TJ-II data retrieving by means of a client/server model, Rev. Sci. Instr. 70 (1) (1999) 498
  3. E. Sánchez, J. Vega, C. Crémy and A. Portas, Accessing TJ-II data with remote procedure call, Rev. Sci. Instr. 72 (1) (2001) 525-529