TJ-II:Soft X-rays: Difference between revisions

From FusionWiki
Jump to navigation Jump to search
No edit summary
(Updated reference links)
 
(2 intermediate revisions by the same user not shown)
Line 5: Line 5:
The [[TJ-II]] multichannel soft X-ray system consists of 5 cameras with 16 channels each,
The [[TJ-II]] multichannel soft X-ray system consists of 5 cameras with 16 channels each,
allowing tomographic reconstruction of the plasma emissions (using the [[EBITA]] code).
allowing tomographic reconstruction of the plasma emissions (using the [[EBITA]] code).
<ref>[http://link.aip.org/link/?RSINAK/70/642/1 F. Medina et al, ''X-ray diagnostic systems for the TJ–II flexible heliac'', Rev. Sci. Instrum. '''70''' (1999) 642]</ref>
<ref>F. Medina et al, ''X-ray diagnostic systems for the TJ–II flexible heliac'', [[doi:10.1063/1.1149517|Rev. Sci. Instrum. '''70''' (1999) 642]]</ref>
<ref>[http://link.aip.org/link/?RSINAK/72/471/1 F. Medina et al, ''Filamentary current detection in stellarator plasmas'', Rev. Sci. Instrum. '''72''' (2001) 471]</ref>
<ref>F. Medina et al, ''Filamentary current detection in stellarator plasmas'', [[doi:10.1063/1.1310579|Rev. Sci. Instrum. '''72''' (2001) 471]]</ref>
<ref>F. Medina, M.A. Ochando, A. Baciero, J. Guasp, ''Characterization of ripple-trapped suprathermal electron losses by their bremsstrahlung emission in the soft x-ray range at the TJ-II stellarator'', [[doi:10.1088/0741-3335/49/4/003|Plasma Phys. Control. Fusion '''49''' (2007) 385]]</ref>


The system is located in [[TJ-II:Sectors|sector]] A2, at &phi; = 112&deg;.
The system is located in [[TJ-II:Sectors|sector]] A2, at &phi; = 104.5&deg;.
The signals are stored in the [[TJ-II:Shot database|TJ-II database]] with the names 'RXxyy', where 'x' = 1,...,5 (corresponding to the five arrays) and 'yy' = 01,...,16 (corresponding to the 16 channels).
The signals are stored in the [[TJ-II:Shot database|TJ-II database]] with the names 'RXxyy', where 'x' = 1,...,5 (corresponding to the five arrays) and 'yy' = 01,...,16 (corresponding to the 16 channels).


== References ==
== References ==
<references />
<references />

Latest revision as of 16:59, 3 April 2018

Multichannel Soft X-Ray system

TJ-II Soft X-Ray camera array

The TJ-II multichannel soft X-ray system consists of 5 cameras with 16 channels each, allowing tomographic reconstruction of the plasma emissions (using the EBITA code). [1] [2] [3]

The system is located in sector A2, at φ = 104.5°. The signals are stored in the TJ-II database with the names 'RXxyy', where 'x' = 1,...,5 (corresponding to the five arrays) and 'yy' = 01,...,16 (corresponding to the 16 channels).

References

  1. F. Medina et al, X-ray diagnostic systems for the TJ–II flexible heliac, Rev. Sci. Instrum. 70 (1999) 642
  2. F. Medina et al, Filamentary current detection in stellarator plasmas, Rev. Sci. Instrum. 72 (2001) 471
  3. F. Medina, M.A. Ochando, A. Baciero, J. Guasp, Characterization of ripple-trapped suprathermal electron losses by their bremsstrahlung emission in the soft x-ray range at the TJ-II stellarator, Plasma Phys. Control. Fusion 49 (2007) 385