TJ-II:Shot database: Difference between revisions

From FusionWiki
Jump to navigation Jump to search
m (Reverted edits by 122.248.210.168 (Talk) to last revision by Admin)
 
(9 intermediate revisions by 5 users not shown)
Line 11: Line 11:
[http://www-fusion.ciemat.es/cgi-bin/dir/dirnew.cgi?manuals/Databases_TJII/ here] (internal laboratory access only).
[http://www-fusion.ciemat.es/cgi-bin/dir/dirnew.cgi?manuals/Databases_TJII/ here] (internal laboratory access only).


* General information about the TJ-II Shot Database<ref>[http://dx.doi.org/10.1016/S0920-3796(00)00133-2 J. Vega, C. Crémy, E. Sánchez, A. Portas, J. A. Fábregas, R. Herrera, ''Data management in the TJ-II multi-layer database'', Fus. Eng. and Design '''48''' (2000) 69-79]</ref>
* General information about the TJ-II Shot Database<ref>J. Vega, C. Crémy, E. Sánchez, A. Portas, J. A. Fábregas, R. Herrera, ''Data management in the TJ-II multi-layer database'', [[doi:10.1016/S0920-3796(00)00133-2|Fus. Eng. and Design '''48''' (2000) 69-79]]</ref>
* [http://fudaqs2.ciemat.es/TJ2WEB/AyudaDatos/index.htm The software library for accessing the raw data]<ref>[http://link.aip.org/link/?RSINAK/70/498/1 J. Vega, E. Sánchez, C. Crémy, A. Portas, C. M. Dulya, J. Nilsson, ''TJ-II data retrieving by means of a client/server model'', Rev. Sci. Instr. '''70''' (1) (1999) 498]</ref>
* [http://fudaqs2.ciemat.es/TJ2WEB/AyudaDatos/index.htm The software library for accessing the raw data]<ref>J. Vega, E. Sánchez, C. Crémy, A. Portas, C. M. Dulya, J. Nilsson, ''TJ-II data retrieving by means of a client/server model'', [[doi:10.1063/1.1149283|Rev. Sci. Instr. '''70''' (1) (1999) 498]]</ref>
* The Remote Procedure Call (RPC) library for accessing data<ref>[http://link.aip.org/link/?RSINAK/72/525/1 E. Sánchez, J. Vega, C. Crémy and A. Portas, ''Accessing TJ-II data with remote procedure call'', Rev. Sci. Instr. '''72''' (1) (2001) 525-529]</ref>
* The Remote Procedure Call (RPC) library for accessing data<ref>E. Sánchez, J. Vega, C. Crémy and A. Portas, ''Accessing TJ-II data with remote procedure call'', [[doi:10.1063/1.1316757|Rev. Sci. Instr. '''72''' (1) (2001) 525-529]]</ref>
* Data access interface routines for MatLab: [http://intranet-fusion.ciemat.es/ Intranet, National Fusion Laboratory (CIEMAT)] / Document Server / Manuals and Software / Matlab acceso datos TJ-II
* [https://www.ciemat.es/portal.do?TR=A&IDR=1&identificador=1093 TJ-II Web Services], a web interface for access to the TJ-II database


== See also ==
== See also ==


* [[TJ-II:Relational database|TJ-II Relational database]]
* [[TJ-II:Relational database|TJ-II Relational database]]
* [[MDSplus]]


== References ==
== References ==
<references />
<references />

Latest revision as of 08:44, 17 July 2024

Raw data and data with minimal processing are stored in the TJ-II Shot Database, which allows storing both time traces and spatial profiles.

Raw data are stored in the database as soon as the data acquisition process of a TJ-II discharge is finished. Relevant accompanying factors (e.g., calibration constants, offsets) can be stored with the data. After storage, the raw data cannot be modified.

Processed data can be incorporated at any time after the discharge, and can be overwritten if needed. The signal names of processed data terminate in an underscore.

Documentation

The documents referred to below are available on-line here (internal laboratory access only).

See also

References

  1. J. Vega, C. Crémy, E. Sánchez, A. Portas, J. A. Fábregas, R. Herrera, Data management in the TJ-II multi-layer database, Fus. Eng. and Design 48 (2000) 69-79
  2. J. Vega, E. Sánchez, C. Crémy, A. Portas, C. M. Dulya, J. Nilsson, TJ-II data retrieving by means of a client/server model, Rev. Sci. Instr. 70 (1) (1999) 498
  3. E. Sánchez, J. Vega, C. Crémy and A. Portas, Accessing TJ-II data with remote procedure call, Rev. Sci. Instr. 72 (1) (2001) 525-529