W7-X: Difference between revisions

From FusionWiki
Jump to navigation Jump to search
No edit summary
Line 48: Line 48:
* [http://www.ipp.mpg.de/ippcms/eng/for/bereiche/w7xaufbau/index.html Wendelstein 7-X] (division)
* [http://www.ipp.mpg.de/ippcms/eng/for/bereiche/w7xaufbau/index.html Wendelstein 7-X] (division)
* [http://www.ipp.mpg.de/ippcms/eng/for/projekte/w7x/index.html Wendelstein 7-X] (project)
* [http://www.ipp.mpg.de/ippcms/eng/for/projekte/w7x/index.html Wendelstein 7-X] (project)
== References ==
* [[doi:10.1063/1.871924|C. Nührenberg, ''Global ideal magnetohydrodynamic stability analysis for the configurational space of Wendelstein 7–X'', Phys. Plasmas '''3''' (1996) 2401]]
* [[doi:10.1109/FUSION.1997.685662|V. Erckmann et al, ''The W7-X project: scientific basis and technical realization'', Fusion Engineering '''6-10''' (1997) 40]]
* [[doi:10.1088/0741-3335/42/11/304|M. Wanner and the W7-X Team, ''Design goals and status of the WENDELSTEIN 7-X project'', Plasma Phys. Control. Fusion '''42''' (2000) 1179]] 
* [[doi:10.1016/S0920-3796(01)00239-3|M. Wanner et al, ''Design and construction of WENDELSTEIN 7-X'', Fusion Engineering and Design '''56-57''' (2001) 155-162]]
* [[doi:10.1088/0029-5515/43/6/304|M. Wanner et al, ''Status of WENDELSTEIN 7-X construction'', Nucl. Fusion '''43''' (2003) 416]]
* [[doi:10.1016/j.fusengdes.2006.07.013|M. Wanner and the W7-X Team, ''Construction and assembly of WENDELSTEIN 7-X'', Fusion Engineering and Design '''81''', 20-22 (2006) 2305-2313]]
* [[doi:10.1016/j.fusengdes.2009.01.106|L. Wegener, ''Status of Wendelstein 7-X construction'', Fusion Engineering and Design '''84''', 2-6 (2009) 106-112]]
* [[doi:10.1109/TPS.2009.2036918|H.-S. Bosch et al, ''Construction of Wendelstein 7-X; Engineering a Steady-State Stellarator'', IEEE Trans. Plasma Science '''38''', 3 (2010) 265]]

Revision as of 11:23, 25 September 2011

W7-X model

Wendelstein 7-X (W7-X) is an experimental stellarator currently being built in Greifswald, Germany by the Max-Planck-Institut für Plasmaphysik (IPP). W7-X is an optimized stellarator, i.e. the magnetic field has been tailored to meet several physical optimization criteria.

Parameter Value Unit
Major radius, R0: 5.5 m
Minor radius, a: 0.53 m
Plasma volume, V: 30 m3
Non-planar coils: 50
Planar coils: 20
Number of ports: 253
Rotational transform, ι/2π: 5/6-5/4
Magnetic field on axis, B0: <3 T
Stored energy, W: 600 MJ
Heating power, P: 15-30 MW
Pulse length: 30 min
Machine height: 4.5 m
Machine diameter: 16 m
Machine mass: 725 t

Optimization criteria