[[TJ-II]] disposes of an eight-channel, high-resolution, spectroscopic diagnostic system. This system is currently being used to measure impurity ion temperature and poloidal rotation using passive emission spectroscopy. The principal features of the diagnostic include independent focusing of its channels, high sensitivity for performing Doppler measurements in low-density [[TJ-II:Electron Cyclotron Resonant Heating|ECR-heated]] plasmas, as well as a flexible and fast in-house-developed software program for performing integrated data reduction and analysis.
[[TJ-II]] disposes of an eight-channel, high-resolution, spectroscopic diagnostic system. This system is currently being used to measure impurity ion temperature and poloidal rotation using passive emission spectroscopy. The principal features of the diagnostic include independent focusing of its channels, high sensitivity for performing Doppler measurements in low-density [[TJ-II:Electron Cyclotron Resonant Heating|ECR-heated]] plasmas, as well as a flexible and fast in-house-developed software program for performing integrated data reduction and analysis.
<ref>[http://link.aip.org/link/?RSINAK/72/971/1 A. Baciero et al, ''A multi-channel spectroscopic system for measuring impurity ion temperatures and poloidal rotation velocities in TJ-II'', Rev. Sci. Instrum. '''72''' (2001) 971]</ref>
<ref>[http://link.aip.org/link/?RSINAK/72/971/1 A. Baciero et al, ''A multi-channel spectroscopic system for measuring impurity ion temperatures and poloidal rotation velocities in TJ-II'', Rev. Sci. Instrum. '''72''' (2001) 971]</ref>
Proton rotation has been measured using spectral line emission from excited fast neutrals created from inner core plasma protons via charge exchange transfer reactions.
<ref>[http://link.aip.org/link/?RSINAK/74/2056/1 B. Zurro et al, ''Investigation of proton rotation measurements using hydrogen line wings in the TJ-II stellarator'', Rev. Sci. Instrum. '''74''' (2003) 2056]</ref>


Another method for measuring absolutely calibrated rotation velocities consists of simultaneously recording the emission lines from the plasma and from a calibration lamp by means of a double fiber-fiber guide.
Another method for measuring absolutely calibrated rotation velocities consists of simultaneously recording the emission lines from the plasma and from a calibration lamp by means of a double fiber-fiber guide.