TJ-II:Searching for AEs suppression scenarios using off-axis ECCD: Difference between revisions

Line 46: Line 46:
== Description of required resources ==
== Description of required resources ==
Required resources:
Required resources:
* Number of plasma discharges or days of operation:  
* Number of plasma discharges or days of operation: One day - 20 useful shots
* Essential diagnostic systems:
* Essential diagnostic systems: Besides the common shot to shot diagnostics (ECE, Thomson, Interferometry, Radiation), all systems providing edge plasma profiles are needed. Moreover, HIBP, Doppler Reflectometer, Mirnov coils (both helicoidal and poloidal arrays) and CNPA meaurements are mandatory. MSE would also be desirable to measure changes induced by ECCD. 
* Type of plasmas (heating configuration):
* Type of plasmas (heating configuration): ECRH + NBI-1 hydrogen plasmas following the heating scheme shown in Figure 1.
* Specific requirements on wall conditioning if any:
* Specific requirements on wall conditioning if any:  
* External users: need a local computer account for data access: yes/no
* External users: need a local computer account for data access: no
* Any external equipment to be integrated? Provide description and integration needs:
* Any external equipment to be integrated? Provide description and integration needs: no


== Preferred dates and degree of flexibility ==
== Preferred dates and degree of flexibility ==
98