TJ-II:Ports: Difference between revisions

3,741 bytes added ,  11 September 2018
No edit summary
 
(11 intermediate revisions by the same user not shown)
Line 1: Line 1:
The table below specifies which diagnostics and devices are connected to each port of [[TJ-II]].
The listing below specifies which diagnostics and devices are connected to each port of [[TJ-II]].
 
__NOTOC__
== [[TJ-II:Sectors|Sector A]] ==
== [[TJ-II:Sectors|Sector A]] ==


90 ≤ φ ≤ 180 °
90 ≤ φ ≤ 180 °


=== Segment A1 ===
{| class="wikitable"  align="center" border="1"
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
!''Port'' !!''Diagnostic or device''!!''Comment''
Line 15: Line 16:
|-
|-
|A1TANG|| ||
|A1TANG|| ||
|}
=== Segment A2 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|A2TOP|| [[TJ-II:Soft_X-rays| Soft X-ray tomography]] ||
|A2TOP|| [[TJ-II:Soft_X-rays| Soft X-ray tomography]] ||
Line 21: Line 27:
|-
|-
|A2BOT|| [[TJ-II:Soft_X-rays| Soft X-ray tomography]] ||
|A2BOT|| [[TJ-II:Soft_X-rays| Soft X-ray tomography]] ||
|}
=== Segment A3 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|A3SIDE|| ||
|A3SIDE|| ||
|-
|-
|A3BOT|| [[TJ-II:Limiter|Limiter]] ||
|A3BOT|| [[TJ-II:Limiter|Limiter]] ||
|}
=== Segment A4 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|A4TOP|| ||
|A4TOP|| [[TJ-II:Reflectometry|AM reflectometer]] (profiles)<br>[[TJ-II:Heavy Ion Beam Probe|Heavy Ion Beam Probe 2]] (injection) ||
|-
|-
|A4SIDE|| ||
|A4SIDE|| [[TJ-II:Heavy Ion Beam Probe|Heavy Ion Beam Probe 2]] (spectrometer) ||
|-
|-
|A4BOT|| ||
|A4BOT|| ||
|}
=== Segment A5 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|A5TOP|| Vacuum feedthrough connector for the A5 [[TJ-II:Magnetics|Rogowski coil and diamagnetic loop ]]||  
|A5TOP|| Vacuum feedthrough connector for the A5 [[TJ-II:Magnetics|Rogowski coil and diamagnetic loop ]]||  
Line 37: Line 58:
|-
|-
|A5BOT|| ||
|A5BOT|| ||
|}
=== Segment A6 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|A6TOP|| ||
|A6TOP|| ||
|-
|-
|A6SIDE|| [[TJ-II:Electron Cyclotron Resonant Heating|ECRH]] (QTL2) ||
|A6SIDE|| [[TJ-II:Electron Cyclotron Resonant Heating|ECRH]] (QTL2) ||
|}
=== Segment A7 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|A7TOP|| ||
|A7TOP|| [[TJ-II:Biasing probe|Biasing probe]]||
|-
|-
|A7SIDE|| [[TJ-II:Charge_exchange_spectroscopy|Charge exchange spectroscopy]] <br> [[TJ-II:Diagnostic neutral beam|Diagnostic neutral beam]]||
|A7SIDE|| [[TJ-II:Charge_exchange_spectroscopy|Charge exchange spectroscopy]] <br> [[TJ-II:Diagnostic neutral beam|Diagnostic neutral beam]]||
|-
|-
|A7BOT|| ||
|A7BOT|| ||
|}
=== Segment A8 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|A8TOP||  ||
|A8TOP||  ||
Line 61: Line 97:
180 &le; &phi; &le; 270 &deg;
180 &le; &phi; &le; 270 &deg;


=== Segment B1 ===
{| class="wikitable"  align="center" border="1"
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
!''Port'' !!''Diagnostic or device''!!''Comment''
Line 71: Line 108:
|-
|-
|B1TANG|| [[TJ-II:Compact Neutral Particle Analyzer|Compact Neutral Particle Analyzer]] ||
|B1TANG|| [[TJ-II:Compact Neutral Particle Analyzer|Compact Neutral Particle Analyzer]] ||
|}
=== Segment B2 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|B2TOP|| ||
|B2TOP|| ||
Line 77: Line 119:
|-
|-
|B2BOT|| [[TJ-II:Langmuir Probes|Langmuir Probes]] ||
|B2BOT|| [[TJ-II:Langmuir Probes|Langmuir Probes]] ||
|}
=== Segment B3 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|B3SIDE|| [[TJ-II:Electron Cyclotron Resonant Heating|ECRH]] (QTL1) ||
|B3SIDE|| [[TJ-II:Electron Cyclotron Resonant Heating|ECRH]] (QTL1) ||
|-
|-
|B3BOT|| ||
|B3BOT|| ||
|}
=== Segment B4 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|B4TOP|| [[TJ-II:Heavy Ion Beam Probe|Heavy Ion Beam Probe]] (injection)||
|B4TOP|| [[TJ-II:Heavy Ion Beam Probe|Heavy Ion Beam Probe 1]] (injection)||
|-
|-
|B4SIDE|| [[TJ-II:Heavy Ion Beam Probe|Heavy Ion Beam Probe]] (spectrometer) <br>Vacuum feedthrough connector for the B4 [[TJ-II:Magnetics|Rogowski coil and diamagnetic loop]] ||
|B4SIDE|| [[TJ-II:Heavy Ion Beam Probe|Heavy Ion Beam Probe 1]] (spectrometer) <br>Vacuum feedthrough connector for the B4 [[TJ-II:Magnetics|Rogowski coil and diamagnetic loop]] ||
|-
|-
|B4BOT|| ||
|B4BOT|| ||
|}
=== Segment B5 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|B5TOP|| Vacuum feedthrough connector for the second [[TJ-II:Magnetics|Mirnov coil straight vertical array]] ||
|B5TOP|| Vacuum feedthrough connector for the second [[TJ-II:Magnetics|Mirnov coil straight vertical array]] ||
Line 93: Line 150:
|-
|-
|B5BOT|| ||
|B5BOT|| ||
|}
=== Segment B6 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|B6TOP|| ||
|B6TOP|| ||
|-
|-
|B6SIDE|| ||
|B6SIDE|| ||
|}
=== Segment B7 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|B7TOP|| [[TJ-II:Bolometry|Multichannel Bolometry]] ||
|B7TOP|| [[TJ-II:Bolometry|Multichannel Bolometry]] ||
Line 103: Line 170:
|-
|-
|B7BOT|| ||
|B7BOT|| ||
|}
=== Segment B8 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|B8TOP|| [[TJ-II:Interferometry|Microwave interferometer]] ||
|B8TOP|| [[TJ-II:Interferometry|Microwave interferometer]] ||
Line 117: Line 189:
270 &le; &phi; &le; 360 &deg;
270 &le; &phi; &le; 360 &deg;


=== Segment C1 ===
{| class="wikitable"  align="center" border="1"
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
!''Port'' !!''Diagnostic or device''!!''Comment''
Line 127: Line 200:
|-
|-
|C1TANG|| [[TJ-II:Neutral Beam Injection|NBI 1]]||
|C1TANG|| [[TJ-II:Neutral Beam Injection|NBI 1]]||
|}
=== Segment C2 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|C2TOP|| ||
|C2TOP|| ||
Line 133: Line 211:
|-
|-
|C2BOT|| ||
|C2BOT|| ||
|}
=== Segment C3 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|C3SIDE|| ||
|C3SIDE|| ||
|-
|-
|C3BOT|| [[TJ-II:Limiter|Limiter]] ||
|C3BOT|| [[TJ-II:Limiter|Limiter]] ||
|}
=== Segment C4 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|C4TOP|| Vacuum feedthrough connector for the first [[TJ-II:Magnetics|Mirnov coil straight vertical array]] ||
|C4TOP|| Vacuum feedthrough connector for the first [[TJ-II:Magnetics|Mirnov coil straight vertical array]] ||
Line 143: Line 231:
|-
|-
|C4BOT|| ||
|C4BOT|| ||
|}
=== Segment C5 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|C5TOP|| ||
|C5TOP|| ||
Line 149: Line 242:
|-
|-
|C5BOT|| ||
|C5BOT|| ||
|}
=== Segment C6 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|C6TOP|| [[TJ-II:Reflectometry#Doppler_Reflectometer|Doppler Reflectometer]] (Mirror) ||  
|C6TOP|| [[TJ-II:Reflectometry#Doppler_Reflectometer|Doppler Reflectometer]] (Mirror) ||  
|-
|-
|C6SIDE|| [[TJ-II:Reflectometry#Doppler_Reflectometer|Doppler Reflectometer]] (Antenna) ||  
|C6SIDE|| [[TJ-II:Reflectometry#Doppler_Reflectometer|Doppler Reflectometer]] (Antenna) ||  
|}
=== Segment C7 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|C7TOP|| ||
|C7TOP|| [[TJ-II:Lithium Beam|Lithium Beam]]||
|-
|-
|C7SIDE|| ||
|C7SIDE|| ||
|-
|-
|C7BOT|| ||
|C7BOT|| ||
|}
=== Segment C8 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|C8TOP|| [[TJ-II:Helium_Beam|Helium beam]] ||
|C8TOP|| [[TJ-II:Helium Beam|Helium Beam]] ||
|-
|-
|C8SIDE|| [[TJ-II:Helium_Beam|Helium beam]] ||
|C8SIDE|| [[TJ-II:Helium Beam|Helium Beam]] ||
|-
|-
|C8BOT|| [[TJ-II:Helium_Beam|Helium beam]] ||
|C8BOT|| [[TJ-II:Helium Beam|Helium Beam]] ||
|-
|-
|C8TANG|| ||
|C8TANG|| ||
Line 173: Line 281:
0 &le; &phi; &le; 90 &deg;
0 &le; &phi; &le; 90 &deg;


=== Segment D1 ===
{| class="wikitable"  align="center" border="1"
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
!''Port'' !!''Diagnostic or device''!!''Comment''
Line 183: Line 292:
|-
|-
|D1TANG|| ||
|D1TANG|| ||
|}
=== Segment D2 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|D2TOP|| [[TJ-II:Thomson Scattering|Thomson Scattering]] (laser view dump) ||
|D2TOP|| [[TJ-II:Thomson Scattering|Thomson Scattering]] (laser view dump) ||
Line 189: Line 303:
|-
|-
|D2BOT|| [[TJ-II:Thomson Scattering|Thomson Scattering]] (laser entry)||
|D2BOT|| [[TJ-II:Thomson Scattering|Thomson Scattering]] (laser entry)||
|}
=== Segment D3 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|D3SIDE|| ||
|D3SIDE|| ||
|-
|-
|D3BOT|| ||
|D3BOT|| ||
|}
=== Segment D4 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|D4TOP|| [[TJ-II:Langmuir Probes|Langmuir probe]] ||
|D4TOP|| [[TJ-II:Langmuir Probes|Langmuir probe]] ||
Line 199: Line 323:
|-
|-
|D4BOT|| ||
|D4BOT|| ||
|}
=== Segment D5 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|D5TOP|| ||
|D5TOP|| ||
Line 205: Line 334:
|-
|-
|D5BOT|| ||
|D5BOT|| ||
|}
=== Segment D6 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|D6TOP|| [[TJ-II:Electron_Bernstein_Wave_Heating|Bernstein Wave Heating]] (mirror) ||
|D6TOP|| [[TJ-II:Electron_Bernstein_Wave_Heating|Bernstein Wave Heating]] (mirror) ||
|-
|-
|D6SIDE|| [[TJ-II:Electron_Bernstein_Wave_Heating|Bernstein Wave Heating]] ||
|D6SIDE|| [[TJ-II:Electron_Bernstein_Wave_Heating|Bernstein Wave Heating]] ||
|}
=== Segment D7 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|D7TOP|| ||
|D7TOP|| ||
Line 215: Line 354:
|-
|-
|D7BOT|| ||
|D7BOT|| ||
|}
=== Segment D8 ===
{| class="wikitable"  align="center" border="1"
!''Port'' !!''Diagnostic or device''!!''Comment''
|-
|-
|D8TOP|| ||
|D8TOP|| ||