<ref>[http://dx.doi.org/10.1016/j.fusengdes.2006.04.014 R. Carrasco et al, ''The NBI control system for the TJ-II'', Fusion Engineering and Design '''81''', Issues 15-17 (2006) 1813-1816]</ref>
=== Vacuum system ===
In order to keep reionization losses at an acceptable level, the maximum allowed pressure during the beam pulse is 10<sup>−4</sup> mbar, which requires an installed pumping speed of 350,000 l/s. Titanium getter pumps have been chosen as the primary vacuum system for these injectors. Base pressures in the range of 5 &times; 10<sup>−9</sup> mbar are attainable with titanium pump operation.
<ref>[http://dx.doi.org/10.1016/S0042-207X(02)00208-7 M. Liniers et al, ''Vacuum system of the neutral beam injectors at the stellarator TJ-II'', Vacuum '''67''', Issues 3-4 (2002) 379-384]</ref>