TJ-II:Interferometry: Difference between revisions

m
no edit summary
mNo edit summary
Line 14: Line 14:
The double wavelength heterodyne interferometer (CO<sub>2</sub>: 10.6 &mu;m, NdYAG: 1.064 &mu;m)  
The double wavelength heterodyne interferometer (CO<sub>2</sub>: 10.6 &mu;m, NdYAG: 1.064 &mu;m)  
provides values of the plasma line integral density in scenarios with average densities ranging from a few times 10<sup>18</sup> m<sup>–3</sup> to more than 5&times;10<sup>19</sup> m<sup>–3</sup>. The results have been compared with those from the 2 mm (microwave) interferometer, obtaining an excellent agreement. Working with a final bandwidth of 4 kHz, a one pass line integral error level about &plusmn;2&times;10<sup>17</sup> m<sup>–2</sup> has been achieved.
provides values of the plasma line integral density in scenarios with average densities ranging from a few times 10<sup>18</sup> m<sup>–3</sup> to more than 5&times;10<sup>19</sup> m<sup>–3</sup>. The results have been compared with those from the 2 mm (microwave) interferometer, obtaining an excellent agreement. Working with a final bandwidth of 4 kHz, a one pass line integral error level about &plusmn;2&times;10<sup>17</sup> m<sup>–2</sup> has been achieved.
<ref>[http://link.aip.org/link/?RSINAK/72/96/1 H. Lamela et al,  ''Laser interferometric experiments for the TJ-II stellarator electron-density measurements'', Rev. Sci. Instrum. '''72''', 96 (2001)]</ref>
<ref>[http://link.aip.org/link/?RSINAK/72/96/1 H. Lamela et al,  ''Laser interferometric experiments for the TJ-II stellarator electron-density measurements'', Rev. Sci. Instrum. '''72''' (2001) 96]</ref>
<ref>[http://link.aip.org/link/?RSINAK/75/3414/1 M. Sánchez at al, ''High resolution CO<sub>2</sub> interferometry on the TJ-II stellarator by using an ADC-based phase meter'', Rev. Sci. Instrum. '''75''', 3414 (2004)]</ref>
<ref>[http://link.aip.org/link/?RSINAK/75/3414/1 M. Sánchez at al, ''High resolution CO<sub>2</sub> interferometry on the TJ-II stellarator by using an ADC-based phase meter'', Rev. Sci. Instrum. '''75''' (2004) 3414]</ref>
<ref>[http://link.aip.org/link/?RSINAK/75/4671/1 P. Acedo et al, ''CO<sub>2</sub> (&lambda;<sub>m</sub> = 10.6 &mu;m) He–Ne (&lambda;<sub>c</sub> = 633 nm) two-color laser interferometry for low and medium electron density measurements in the TJ-II Stellarator'', Rev. Sci. Instrum. '''75''', 11 (2004) 4671]</ref>
<ref>[http://link.aip.org/link/?RSINAK/75/4671/1 P. Acedo et al, ''CO<sub>2</sub> (&lambda;<sub>m</sub> = 10.6 &mu;m) He–Ne (&lambda;<sub>c</sub> = 633 nm) two-color laser interferometry for low and medium electron density measurements in the TJ-II Stellarator'', Rev. Sci. Instrum. '''75''', 11 (2004) 4671]</ref>
The system is located in [[TJ-II:Sectors|sector]] B1.
The system is located in [[TJ-II:Sectors|sector]] B1.