===60 keV DANFYSIK ION IMPLANTER===
===60 keV DANFYSIK ION IMPLANTER===
[[File:Foto0045.jpg|500px|thumb|right|electron accelerator]]
This facility permits ion implantation from 0 up to 60 keV with currents up 150 µA depending on the ion. Particularly helium, hydrogen and duterium has been implanted during the last years making use of this implanter for different tasks related with  fusion research. The same implanter  staff design and develop different irradiation chambers and experimental set-ups depending on implantation characteristics. The developed experimental systems permit making optical, electrical and desorption experiments in the implanter beam line, in-situ. Particularly simultaneous ionoluminescence and surface electrical conductivity measurements can be made  allowing correlation between macroscopic material degradation and defects produced by implnatation.  
This facility permits ion implantation from 0 up to 60 keV with currents up 150 µA depending on the ion. Particularly helium, hydrogen and duterium has been implanted during the last years making use of this implanter for different tasks related with  fusion research. The same implanter  staff design and develop different irradiation chambers and experimental set-ups depending on implantation characteristics. The developed experimental systems permit making optical, electrical and desorption experiments in the implanter beam line, in-situ. Particularly simultaneous ionoluminescence and surface electrical conductivity measurements can be made  allowing correlation between macroscopic material degradation and defects produced by implnatation.  


Line 52: Line 56:


In-situ measurement capability and expertise.
In-situ measurement capability and expertise.
At this facility different studies on candidate fusion insulators have been carried out, in particular electrical, optical and hydrogen and helium diffusion properties are measured regularly in-situ.  These studies are carried out at controlled temperature, from liquid nitrogen up to 1000 C. Available special irradiation chambers and sample holders have been designed by the implanter staff and fabricated at the Ciemat workshops.  
At this facility different studies on candidate fusion insulators have been carried out, in particular electrical, optical and hydrogen and helium diffusion properties are measured regularly in-situ.  These studies are carried out at controlled temperature, from liquid nitrogen up to 1000 C. Available special irradiation chambers and sample holders have been designed by the implanter staff and fabricated at the Ciemat workshops.
 
 


===NAYADE Co-60 irradiation facility===