4,415
edits
No edit summary |
|||
(7 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
== Proposal title == | == Proposal title == | ||
'''Dependence of NBI-driven | '''Dependence of NBI-driven Alfven Eigenmodes on energy and power of the neutral beams in a current compensated scenario''' | ||
== Name and affiliation of proponent == | == Name and affiliation of proponent == | ||
Á. Cappa, E. Ascasíbar, M. Liniers LNF-CIEMAT | Á. Cappa, E. Ascasíbar, M. Liniers, F.Castejón | ||
LNF-CIEMAT | |||
== Details of contact person at LNF (if applicable) == | == Details of contact person at LNF (if applicable) == | ||
Line 24: | Line 26: | ||
the NBI phase in order to control the plasma density. | the NBI phase in order to control the plasma density. | ||
*Target plasma using ECRH, then ECRH is switched off and only used if good density control is not achieved. | *Target plasma using ECRH, then ECRH is switched off and only used if good density control is not achieved. | ||
*Three different values of NBI power shall be used, using the same power in both injectors and the same voltage-current pair. | *Three different values of NBI power shall be used, using the same power in both injectors and the same voltage-current pair. | ||
Line 31: | Line 33: | ||
constant plasma current which ideally should mainly come from the bootstrap contribution. | constant plasma current which ideally should mainly come from the bootstrap contribution. | ||
*Two reproducible shots per voltage | *Two reproducible shots per voltage. Alternatively, the length of one of the beams may be 20-30 ms shorter than the | ||
other one in order to isolate the mode excitation that corresponds to each beam and identify which beam drives which modes. | |||
*24 shots in total. One day of operation. | *24 shots in total. One day of operation. | ||
Line 43: | Line 46: | ||
* Essential diagnostic systems: Mirnov Coils (poloidal and new helicoidal array), rest of magnetic fluctuations diagnostics, all standard diagnostics (Thomson, ECE, Radiation, Interferometry), Doppler reflectometry, HIBP. | * Essential diagnostic systems: Mirnov Coils (poloidal and new helicoidal array), rest of magnetic fluctuations diagnostics, all standard diagnostics (Thomson, ECE, Radiation, Interferometry), Doppler reflectometry, HIBP. | ||
* Type of plasmas (heating configuration): 100_44_64 | * Type of plasmas (heating configuration): 100_44_64 | ||
* Specific requirements on wall conditioning if any: | * Specific requirements on wall conditioning if any: Good density control | ||
* External users: need a local computer account for data access: | * External users: need a local computer account for data access: No external users | ||
* Any external equipment to be integrated? | * Any external equipment to be integrated? No | ||
== Preferred dates and degree of flexibility == | == Preferred dates and degree of flexibility == | ||
Line 59: | Line 62: | ||
[[Category:TJ-II internal documents]] | [[Category:TJ-II internal documents]] | ||
[[Category:TJ-II experimental proposals]] | [[Category:TJ-II experimental proposals Spring 2018]] |