TJ-II:Interferometry: Difference between revisions

Line 3: Line 3:
== The Microwave interferometer ==
== The Microwave interferometer ==


The probing beam has a frequency of 140 GHz, corresponding to a wavelength of λ = 2.14 mm.
The diagnostic is located in [[TJ-II:Sectors|sector]] B8.
The probing beam has an inclination of 18.7º with respect to the vertical and a frequency of 140 GHz, corresponding to a wavelength of λ = 2.14 mm.
The diagnostic provides a time trace of the-line integrated electron density (65536 points, sampling rate 100 kHz).
The diagnostic provides a time trace of the-line integrated electron density (65536 points, sampling rate 100 kHz).
The signal is less reliable for high densities (above 2-3 10<sup>19</sup> m<sup>-3</sup>).
The signal is less reliable for high densities (above 2-3 10<sup>19</sup> m<sup>-3</sup>).