[[TJ-II]] disposes of Heavy Ion Beam Probe systems.
== HIBP 1 ==
[[File:TJ-II_HIBP_diagram.png|350px|thumb|right|HIBP probe diagram]]
[[File:TJ-II_HIBP_diagram.png|350px|thumb|right|HIBP probe diagram]]


At [[TJ-II]], the advanced Heavy Ion Beam Probe can simultaneously measure the plasma electric potential ''&phi;'', the electron density ''n<sub>e</sub>'', and a poloidal magnetic field component ''B<sub>p</sub>'' at a point inside the plasma.
The advanced Heavy Ion Beam Probe can simultaneously measure the plasma electric potential ''&phi;'', the electron density ''n<sub>e</sub>'', and a poloidal magnetic field component ''B<sub>p</sub>'' at a point inside the plasma.
<ref>[http://link.aip.org/link/?RSINAK/72/583/1 I.S. Bondarenko et al., ''Installation of an advanced heavy ion beam diagnostic on the TJ-II stellarator'', Rev. Sci. Instrum. '''72''', 583 (2001)]</ref>
<ref>[http://link.aip.org/link/?RSINAK/72/583/1 I.S. Bondarenko et al., ''Installation of an advanced heavy ion beam diagnostic on the TJ-II stellarator'', Rev. Sci. Instrum. '''72''', 583 (2001)]</ref>
<ref>[http://dx.doi.org/10.1016/S0920-3796(01)00428-8 L.I. Krupnik et al., ''The first operation of the advanced heavy ion beam probing diagnostic on the TJ-II flexible heliac'', Fusion Engineering and Design '''56-57''' (2001) 935]</ref>
<ref>[http://dx.doi.org/10.1016/S0920-3796(01)00428-8 L.I. Krupnik et al., ''The first operation of the advanced heavy ion beam probing diagnostic on the TJ-II flexible heliac'', Fusion Engineering and Design '''56-57''' (2001) 935]</ref>
Line 12: Line 16:
<ref>[http://link.aip.org/link/?RSINAK/75/3511/1 B. Gonçalves et al, ''Operation of a multiple cell array detector in plasma experiments with a heavy ion beam diagnostic'', Rev. Sci. Instrum. '''75''' (2004) 3511]</ref>
<ref>[http://link.aip.org/link/?RSINAK/75/3511/1 B. Gonçalves et al, ''Operation of a multiple cell array detector in plasma experiments with a heavy ion beam diagnostic'', Rev. Sci. Instrum. '''75''' (2004) 3511]</ref>
The system is located in [[TJ-II:Sectors|sector]] B4.
The system is located in [[TJ-II:Sectors|sector]] B4.
A second, similar system is currently being installed in [[TJ-II:Sectors|sector]] A4.
[[File:TJ-II_HIBP.png|350px|thumb|right|HIBP probe composite photo (taken around 2002)]]
[[File:TJ-II_HIBP.png|350px|thumb|left|HIBP probe composite photo (taken around 2002)]]
 
== HIBP 2 ==
 
A second, similar system is currently being installed in [[TJ-II:Sectors|sector]] A4 (see photo).
[[File:IMG 1627.JPG|350px|thumb|right|Installation of the second HIBP probe (January, 2011)]]
 


== Operation principle ==
== Operation principle ==
Line 21: Line 30:
===Formal expression of the electric potential <math>\phi</math>===
===Formal expression of the electric potential <math>\phi</math>===
Refering to the figure, we will denote as <math>A</math>, <math>B</math> and <math>C</math> the injection, ionization and detection points respectively. The Hamiltonian of a charge in an electromagnetic field is
Refering to the figure, we will denote as <math>A</math>, <math>B</math> and <math>C</math> the injection, ionization and detection points respectively. The Hamiltonian of a charge in an electromagnetic field is
[[Image:HIBP3.png|256px|thumb|left|alt=Schematic HIBP operation principle.|Schematic HIBP operation principle.]]
[[Image:HIBP3.png|256px|thumb|right|alt=Schematic HIBP operation principle.|Schematic HIBP operation principle.]]


:<math>
:<math>