[[File:Thomson.png|400px|thumb|right|The Thomson Scattering diagnostic at TJ-II]] | [[File:Thomson.png|400px|thumb|right|The Thomson Scattering diagnostic at TJ-II]] | ||
The high-resolution Thomson Scattering system | The high-resolution Thomson Scattering system | ||
(located in [[TJ-II:Sectors|sector]] D2, φ = 14.5°) | (located in [[TJ-II:Sectors|sector]] D2, φ = 14.5°) | ||
provides electron temperature, density, and pressure profiles at a single time in the discharge. | provides electron temperature, density, and pressure profiles at a single time in the discharge. | ||
<ref>[http://link.aip.org/link/?RSINAK/70/763/1 C.J. Barth et al, ''High-resolution multiposition Thomson scattering for the TJ-II stellarator'', Rev. Sci. Instruments, Vol. '''70''', 1 (1999) 763-767]</ref> | |||
<ref>[http://link.aps.org/doi/10.1103/PhysRevLett.85.4715 J. Herranz, I. Pastor, F. Castejón, E. de la Luna, I. García-cortés, C.J. Barth, E. Ascasíbar, J. Sánchez, and V. Tribaldos, ''Profile structures of TJ-II stellarator plamsas'', Phys. Rev. Lett. '''85''' (2000) 4715]</ref> | |||
<ref>[http://link.aip.org/link/?RSINAK/72/3514/1 C.J. Barth et al, ''Calibration procedure and data processing for a TV Thomson scattering system'', Rev. Sci. Instruments, Vol. '''72''', 9 (2001) 3514-3527]</ref> | |||
<ref>J. Herranz et al. ''Analysis of the Detection Process and Error Sources for the Thomson Scattering Profile Measurement in TJ-II''. Proc. issues of the 14th Topical Conf. on High Temperature Plasma Diagnostics, A.P.S., July 8, 2002, Madison, WI</ref> | |||
<ref>[http://dx.doi.org/10.1016/S0920-3796(03)00387-9 J. Herranz et al, ''The spectrometer of the high-resolution multiposition Thomson scattering diagnostic for TJ-II'', Fus. Eng. And Design, '''65''' (2003) 525-536]</ref> | |||
<ref>[http://link.aip.org/link/?RSINAK/74/3998/1 B.Ph. van Milligen et al, ''Revision of TV Thomson scattering data analysis and detection of profile structure'', Rev. Sci. Instrum. '''74''' (2003) 3998]</ref> | |||
The laser chord is inclined by 17° from the vertical. | The laser chord is inclined by 17&deg; from the vertical. | ||
For reliable operation of the diagnostic, the parameters of the plasma should lie in the design range. | For reliable operation of the diagnostic, the parameters of the plasma should lie in the design range. | ||
Line 19: | Line 20: | ||
'''Wavelength calibration''': The spectrometer is illuminated with light coming from Helium and Argon spectral lamps, both having well documented, intense lines in the range from 550 to 850 nm. | '''Wavelength calibration''': The spectrometer is illuminated with light coming from Helium and Argon spectral lamps, both having well documented, intense lines in the range from 550 to 850 nm. | ||
'''Position calibration''': A set of ∼ 20 carefully aligned pinholes, (diameter 300 microns, separation 20 mm), illuminated by a tungsten lamp, are imaged onto the spectrometer, to provide position calibration along the laser chord. In order to obtain the effective radius, the precise location of the laser chord and optical axis of the spectrometer with respect to TJII must be known. This measurement was performed when the system was first installed. | '''Position calibration''': A set of &sim; 20 carefully aligned pinholes, (diameter 300 microns, separation 20 mm), illuminated by a tungsten lamp, are imaged onto the spectrometer, to provide position calibration along the laser chord. In order to obtain the effective radius, the precise location of the laser chord and optical axis of the spectrometer with respect to TJII must be known. This measurement was performed when the system was first installed. | ||
'''Relative calibration''': This procedure is used to calibrate the relative response of the spectrometer as a function of wavelength and position. A tungsten-halogen lamp with a known, broad spectrum (black-body like) is used to this effect. The current in the lamp is kept constant by using a regulated power supply. | '''Relative calibration''': This procedure is used to calibrate the relative response of the spectrometer as a function of wavelength and position. A tungsten-halogen lamp with a known, broad spectrum (black-body like) is used to this effect. The current in the lamp is kept constant by using a regulated power supply. | ||
'''Absolute calibration''': in order to provide absolute density calibration, Rayleigh scattering with N | '''Absolute calibration''': in order to provide absolute density calibration, Rayleigh scattering with N<sub>2</sub>, CO<sub>2</sub> or other gases has been used. This method is hard to implement in TJII due to the large amount of stray light entering the spectrometer that makes the evaluation of Rayleigh scattering signal from the gas problematic. Other techniques, like evaluation of the absolute density factor in profiles at or near to an ECRH cut-off have been tried. Regular comparisons with data from the interferometer can be used as a method to get the absolute density factor on profiles. The shape of the ''n<sub>e</sub>'' profile is nevertheless robust, since it depends only on the relative calibration. | ||
== Data description == | == Data description == | ||
Line 33: | Line 34: | ||
== References == | == References == | ||