4,422
edits
Line 4: | Line 4: | ||
The diagnostic is located in [[TJ-II:Sectors|sector]] B8. | The diagnostic is located in [[TJ-II:Sectors|sector]] B8. | ||
The probing beam has an inclination of 18. | The probing beam has an inclination of 18.7° with respect to the vertical and a frequency of 140 GHz, corresponding to a wavelength of λ = 2.14 mm. | ||
The diagnostic provides a time trace of the line-integrated electron density (65536 points, sampling rate 100 kHz). | The diagnostic provides a time trace of the line-integrated electron density (65536 points, sampling rate 100 kHz). | ||
The time trace is called 'Densidad2_' in the [[TJ-II:Shot_database|TJ-II database]]. | The processed time trace is called 'Densidad2_' in the [[TJ-II:Shot_database|TJ-II database]] (raw data: 'INTERI', 'INTERQ'). | ||
The signal is less reliable for high densities (above 2-3 10<sup>19</sup> m<sup>-3</sup>). | The signal is less reliable for high densities (above 2-3 10<sup>19</sup> m<sup>-3</sup>). | ||
This time trace is fundamental for machine operation. | This time trace is fundamental for machine operation. |