=== Vacuum vessel === | === Vacuum vessel === | ||
The all-metal [[TJ-II:Vacuum system|TJ-II vacuum vessel]] has a helical geometry and has 96 [[TJ-II:Ports|ports]]. | The all-metal [[TJ-II:Vacuum system|TJ-II vacuum vessel]] has a helical geometry and has 96 [[TJ-II:Ports|ports]]. | ||
<ref>[http://dx.doi.org/10.1109/FUSION.1991.218780 J. Botija and M. Blaumoser, '' Vacuum vessel design for the TJ-II device'', 14<sup>th</sup> IEEE/NPSS Symposium on Fusion Engineering '''2''' (1991) 992-995]</ref> | |||
The vacuum vessel is made of non-magnetic steel (304 LN) with a thickness of 10 mm. | The vacuum vessel is made of non-magnetic steel (304 LN) with a thickness of 10 mm. | ||
The octants with flanges have been manufactured separately and were assembled in-situ by welding. This assembly was done directly around the central conductor CC/HX, already placed in position. The CC/HX coil is outside of the vacuum vessel thanks to a helical groove built into the vessel. | The octants with flanges have been manufactured separately and were assembled in-situ by welding. This assembly was done directly around the central conductor CC/HX, already placed in position. The CC/HX coil is outside of the vacuum vessel thanks to a helical groove built into the vessel. |